A hybrid mock circulatory system: Testing a prototype under physiologic and pathological conditions(250 views) Ferrari G, De Lazzari C, Kozarski M, Clemente F, Górczy ska K, Mimmo R, Monnanni E, Tosti G, Guaragno M
Ist. di Tecnologie Biomediche CNR, Reparto di Ingegneria Cardiovasc., Viale C. Marx 43, Rome 00137, Italy
References: Geertsema, A.A., Rakhorst, G., Mihaylov, D., Blanksma, P.K., Verkerke, G.J., Development of a numerical simulation model of the cardiovascular system (1997) Artif Organs, 21, pp. 1297-130
Zhou, J., Armstrong, G.P., Medvedev, A.L., Smith, W.A., Golding, L.A., Thomas, J.D., Numerical modeling of the cardiovascular system with a left ventricular assist device (1999) ASAIOJ, 45, pp. 83-89
Pantalos, G.M., Sharp, M.K., Woodruff, S.J., Influence of gravity on cardiac performance (1998) Ann Biomed Eng, 26, pp. 931-943
Bowles, C.T., Shah, S.S., Nishimura, K., Development of mock circulation models for the assessment of counter pulsation systems (1991) Cardiovasc Res, 11, pp. 901-908
Schima, H., Baumgartner, H., Spitaler, F., Kuhn, P., Wolner, E., A modular mock circulation for hydromechanical studies on valves, stenoses, vascular grafts and cardiac assist devices (1992) Int J Artif Organs, 15, pp. 417-421
Knierbein, B., Reul, H., Eilers, R., Lange, M., Kaufmann, R., Rau, C., Compact mock loops of the systemic and pulmonary circulation for blood pump testing (1992) Int J Artif Organs, 15, pp. 40-48
Woodard, J.C., Rock, S.M., Portner, P.M., A sophisticated electromechanical ventricular simulator for ventricular assist system testing (1991) ASAIO Trans, 37, pp. M210-M211
Clemente, F., Ferrari, G., De Lazzari, C., Tosti, G., Technical standards for medical devices: Assisted circulation devices (1997) Technol Health Care, 5, pp. 19-34
Sagawa, K., Maughan, L., Suga, H., Sunagawa, K., (1988) Cardiac Contraction and the Pressure-Volume Relationship, , New York: Oxford University Press
Ferrari, G., Kozarski, M., De Lazzari, C., A hybrid (numerical-physical) model of the left ventricle (2001) Int J Artif Organs, 24, pp. 456-462
Ferrari, G., Nicoletti, A., De Lazzari, C., A physical model of human systemic arterial tree (2000) Int J Artif Organs, 23, pp. 647-657
Gilbert, J.C., Glantz, S.A., Determinants of left ventricular filling and of the diastolic pressure-volume relation (1989) Circ Res, 64, pp. 827-852
Suga, H., Total mechanical energy of a ventricle model and cardiac oxygen consumption (1979) Am J Physiol, 236, pp. H498-H505
Ferrari, G., Górczyńska, K., Mimmo, R., Mono and bi-ventricular assistance: Their effect on ventricular energetics (2001) Int J Artif Organs, 24, pp. 380-391
Westerhof, N., Elzinga, G., Sipkema, P., An artificial arterial system for pumping hearts (1971) J Appl Physiol, 31, pp. 776-781
Geertsema, A. A., Rakhorst, G., Mihaylov, D., Blanksma, P. K., Verkerke, G. J., Development of a numerical simulation model of the cardiovascular system (1997) Artif Organs, 21, pp. 1297-130
Pantalos, G. M., Sharp, M. K., Woodruff, S. J., Influence of gravity on cardiac performance (1998) Ann Biomed Eng, 26, pp. 931-943
Bowles, C. T., Shah, S. S., Nishimura, K., Development of mock circulation models for the assessment of counter pulsation systems (1991) Cardiovasc Res, 11, pp. 901-908
Woodard, J. C., Rock, S. M., Portner, P. M., A sophisticated electromechanical ventricular simulator for ventricular assist system testing (1991) ASAIO Trans, 37, pp. M210-M211
Gilbert, J. C., Glantz, S. A., Determinants of left ventricular filling and of the diastolic pressure-volume relation (1989) Circ Res, 64, pp. 827-852
Ferrari, G., G rczy ska, K., Mimmo, R., Mono and bi-ventricular assistance: Their effect on ventricular energetics (2001) Int J Artif Organs, 24, pp. 380-391
A hybrid mock circulatory system: Testing a prototype under physiologic and pathological conditions
Hydraulic models of circulation are used to test mechanical heart assist devices and for research and training purposes. However, when compared with numerical models, they are rather expensive and often not sufficiently flexible or accurate. Flexibility and accuracy can be improved by merging numerical models with physical models, thus obtaining a hybrid model where numerical and physical sections are connected by an electrohydraulic interface. This concept is applied here to represent left ventricular function. The resulting hybrid model is inserted into the existing closed loop model of circulation. The hybrid model reproduces ventricular function by a variable elastance numerical model. Its interaction with the hydraulic sections is governed by measuring left atrial and systemic arterial pressures and computing the left ventricular output flow by the resolution of the corresponding equations. This signal is used to control a flow generator reproduced by a gear pump driven by a DC motor. Results obtained under different circulatory conditions demonstrate the behavior of the ventricular model on the pressure-volume plane and report the trend of the main hemodynamic variables.
A hybrid mock circulatory system: Testing a prototype under physiologic and pathological conditions
Kim YH, Shin SW, Pellicano R, Fagoonee S, Choi IJ, Kim YI, Park B, Choi JM, Kim SG, Choi J, Park JY, Oh S, Yang HJ, Lim JH, Im JP, Kim JS, Jung HC, Ponzetto A, Figura N, Malfertheiner P, Choi IJ, Kook MC, Kim YI, Cho SJ, Lee JY, Kim CG, Park B, Nam BH, Bae SE, Choi KD, Choe J, Kim SO, Na HK, Choi JY, Ahn JY, Jung KW, Lee J, Kim DH, Chang HS, Song HJ, Lee GH, Jung HY, Seta T, Takahashi Y, Noguchi Y, Shikata S, Sakai T, Sakai K, Yamashita Y, Nakayama T, Leja M, Park JY, Murillo R, Liepniece-karele I, Isajevs S, Kikuste I, Rudzite D, Krike P, Parshutin S, Polaka I, Kirsners A, Santare D, Folkmanis V, Daugule I, Plummer M, Herrero R, Tsukamoto T, Nakagawa M, Kiriyama Y, Toyoda T, Cao X, Corral JE, Mera R, Dye CW, Morgan DR, Lee YC, Lin JT, Garcia Martin R, Matia Cubillo A, Lee SH, Park JM, Han YM, Ko WJ, Hahm KB, Leontiadis GI, Ford AC, Ichinose M, Sugano K, Jeong M, Park JM, Han YM, Park KY, Lee DH, Yoo JH, Cho JY, Hahm KB, Bang CS, Baik GH, Shin IS, Kim JB, Suk KT, Yoon JH, Kim YS, Kim DJ * Helicobacter pylori Eradication for Prevention of Metachronous Recurrence after Endoscopic Resection of Early Gastric Cancer(341 views) N Engl J Med (ISSN: 0028-4793, 0028-4793linking, 1533-4406electronic), 2015 Jun; 30642104201566393291: 749-756. Impact Factor:59.558 ViewExport to BibTeXExport to EndNote
Hesse B, Tagil K, Cuocolo A, Anagnostopoulos C, Bardies M, Bax J, Bengel F, Busemann Sokole E, Davies G, Dondi M, Edenbrandt L, Franken P, Kjaer A, Knuuti J, Lassmann M, Ljungberg M, Marcassa C, Marie PY, Mckiddie F, O'connor M, Prvuolovich E, Underwood R * 3. 0 T perfusion MR imaging(731 views) Rivista Di Neuroradiologia (ISSN: 1120-9976), 2004; 17(6): 807-812. Impact Factor:0.023 ViewExport to BibTeXExport to EndNote