Performance evaluation of the fully engineered YAP-(S)PET scanner for small animal imaging(412 views) Del Guerra A, Bartoli A, Belcari N, Herbert D, Motta A, Vaiano A, Di Domenico G, Sabba N, Moretti E, Zavattini G, Lazzarotti M, Sensi L, Larobina M
Keywords: Molecular Imaging, Positron Emission Tomography (pet), Single Photon Emission Tomography, Small Animal Imaging, Position Sensitive Photomultiplier (ps-Pmt), Imaging Techniques, Optical Collimators, Scanning, Sensitivity Analysis, Switching, Algorithms, Computer Simulation, Crystals, Electron Beam Computed Tomography, Photodiodes, Thin Films, Lutetium Oxyorthosilicate (lso) Crystals, Phantoms, Pixellated Array, Living Systems Studies,
Affiliations: *** IBB - CNR ***
Department of Phyaics, Center of Excellence AmbiSEN and INFN Pisa, University of Pisa, I-56127 Pisa, Italy
Department of Physics, INFN Ferrara, University of Ferrara, I-44100 Ferrara, Italy
I.S.E. Ingegneria dei Sistemi Elettronici s.r.l., I-56010 Vecchiano (PI), Italy
CNR, Istituto di Biostrutture e Bioimmagini, I-80100 Napoli, Italy
Laboratory of Nuclear Medicine and Molecular Imaging, Department of Radiological Sciences, University of Ferrara, I-44100 Ferrara, Italy
C.N.R - Istituto di Biostrutture e Bioimmagini, Napoli, Italy
C. N. R - Istituto di Biostrutture e Bioimmagini, Napoli, Italy
I. S. E. Ingegneria dei Sistemi Elettronici s. r. l., I-56010 Vecchiano (PI), Italy
References: Not available.
Performance evaluation of the fully engineered YAP-(S)PET scanner for small animal imaging
At the Department of Physics of the University of Pisa, Italy, a new and fully engineered version of the YAP-(S)PET small animal scanner has been recently installed. The new YAP-(S)PET is able to perform both PET and SPECT studies on small animals. The scanner is made up of four heads: each one is composed of a 4 x 4 cm(2) YAlO3:Ce (or YAP:Ce) matrix of 20 x 20 elements, 2 x 2 x 25 mm(3) each, coupled to a Position Sensitive Photomultiplier (PS-PMT) (Hamamatsu R2486). The four modules are positioned on a rotating gantry. The switching to the SPECT modality is easily made by mounting a high resolution parallel hole (0.6 mm circle divide, 0.15 mm septum) lead collimator in front of each crystal. This paper reports the performance of the system in terms of absolute sensitivity and spatial resolution for both PET and SPECT modalities. The scatter fraction and noise-equivalent count rate (NEC) for a mouse phantom for different energy windows have been measured in PET modality. Images of phantoms and animals are also presented.
Performance evaluation of the fully engineered YAP-(S)PET scanner for small animal imaging