A Study On Two Different Cad Systems For Mmammography As An Aid To Radiological Diagnosis In The Search Of Microcalcification Clusters(338 views) Lauria A, Palmiero R, Forni G, Fantacci ME, Imbriaco M, Sodano A, Indovina PL
Keywords: Breast Cancer, Calma, Computer Aided Detection, Mammography, Calcification (biochemistry), Computer Aided Diagnosis, Diagnostic Radiography, Image Analysis, Radiology, Sensitivity Analysis, Computer Aided Detection (cad), Digital Mammography, Digitized Mammograms, Microcalcification, Adult, Article, Cluster Analysis, Computer Aided Design, Diagnostic Accuracy, Follow Up, Histopathology, Human, Imaging, Major Clinical Study, Medical Practice, Prediction, Priority Journal, Public Hospital, Qualitative Analysis, Radiodiagnosis, Radiologist, Sensitivity And Specificity, Breast Diseases, Calcinosis, Computer-Assisted, Female, Predictive Value Of Tests, Radiographic Image Interpretation, Roc Curve, Software,
Affiliations: *** IBB - CNR ***
Struttura Dipartimentale di Matematica e Fisica dell'Università di Sassari, INFN-Sezione di Napoli, Complesso Universitario Monte S. Angelo, Via Cinthia, I-80126, Napoli, Italy
INFN-Sezione di Pisa, Dipartimento di Fisica, Università di Pisa, via Livornese 1261, I-56010, San Piero a Grado, Pisa, Italy
Dipartimento di Radiologia, Istituto di Biostrutture e Bioimmagini (I.B.B.), via Pansini 5, I-80131 Napoli, Italy
Dipartimento di Scienze Biomorfologiche e Funzionali, Università di Napoli Federico II, via Pansini 5, I-80131 Napoli, Italy
References: Haus, A.G., Yaffe, M., A cathegorical course in physics. Technical aspects in breast imaging (1993) Presented at the 79th Scientific Assembly and Annual Meeting of RSNA1993, , Radiological Society of North Americ
Thurfjell, E., Anders Lernevall, K., Taube, A., Benefit of independent double reading in a population-based mammography screening program (1994) Radiology, 191, pp. 241-244
Anttinen, I., Pamilo, M., Soiva, M., Roiha, M., Double reading of mammography screening films-one radiologist or two? (1993) Clin Radiol, 48, pp. 414-421
www.cadxmed.comhttp://www.kodak.com/US/en/corp/pressReleases/pr20040801-01.shtmlwww.mirada-solutions.comwww.r2tech.comwww.scanis.comJong, R.A., Yaffe, M.J., Skarpathiotakis, M., Contrast-enhanced digital mammography: Initial clinical experience (2003) Radiology, 228, pp. 842-850
Amendolia, S.R., Bisogni, M.G., Bottigli, U., The CALMA project: A CAD tool in breast radiography (2001) Nucl Instrum Methods, 460, pp. 107-112
Palmiero, R., Lauria, A., Forni, G., The CALMA system: An artificial neural network method for detecting masses and microcalcifications in digitised mammograms (2004) Nucl Instrum Methods a, 518, pp. 391-393
Kegelmeyer, W.P., Pruneda, J.M., Bourland, P.D., Hillis, A., Riggs, M.W., Nipper, M.L., Computer-aided mammographic screening for spiculated lesions (1994) Radiology, 191, pp. 331-337
Huo, Z., Giger, M.L., Vyborny, C.J., Analysis of spiculation in the computerized classification of mammographic masses (1995) Med Phys, 22, pp. 1569-1579
Freer, V.T., Ulissey, M.J., Screening mammograpy with computer-aided detection: Prospective study of 12,860 patients in a community breast center (2001) Radiology, 220, pp. 781-786
Brake, G.M., Karssemeijer, N., Hendriks, J.H.C.L., Automated detection of breast carcinomas not detected in a screening program (1998) Radiology, 207, pp. 465-471
Birdwell, R.L., Ikeda, D.M., O'Shaughnessy, K.F., Sickles, E.A., Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection (2001) Radiology, 219, pp. 192-202
Burhenne, L.J., Wood, S.A., D'Orsi, C., Potential contribution of computer-aided detection to the sensitivity of srcreening mammography (2000) Radiology, 215, pp. 554-562
Taft, R., Taylor, A., Potential improvement in breast cancer detection with a novel computer-aided detection system (2001) Appl Radiol, 12, pp. 25-28
Ciatto, S., Rosselli Del Turco, M., Risso, G., Comparison of standard and computer aided diagnosis (CAD) on a national proficiency test of screening mammography (2003) Eur J Radiol, 45, pp. 135-138
Malich, A., Marx, C., Facius, M., Boehm, T., Fleck, M., Kaiser, W.A., Tumour detection rate on a new commercially available computer aided detection system (2001) Eur Radiol, 11, pp. 2454-2459
Bazzocchi, M., Facecchia, I., Zuiani, C., Applicazioni di un sistema di computer aided detection (CAD) a mammografie digitalizzate nell'individuazione di microcalcificazioni (2001) Radiol Med, 101, pp. 334-340
Malich, A., Vogel, D., Facius, M., Marx, C., Freesmeyer, M.G., Sauner, D., Evaluation of the primary diagnosis with a CAD-system in mammography (2003) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr, 175 (9), pp. 1225-1231
Bottigli, U., Delogu, P., Fantacci, M.E., Search of Microcalcification clusters with the CALMA CAD station (2002) Int Soc Opt Eng (SPIE), 4684, pp. 1301-1310
Metz, C.E., ROC methodology in radiological imaging (1986) Invest Radiol, 21, pp. 720-733
Green, D.N., Swets, J.A., (1966) Signal Detection Theory and Psychophysics, , John Wiley and Sons New York
www.medcalc.beHuo, Z., Giger, M.L., Vyborny, C.J., Metz, C.E., Breast cancer: Effectiveness of computer-aided diagnosis-observer study with independent database of mammograms (2002) Radiology, 224, pp. 560-568
Hays, W.L., (1963) Statistics for Psychologists, , Rinehart and Winston, Inc. Holt
Jiang, Y., Nishikawa, R.M., Schmidt, R.A., Toledano, A.Y., Doi, K., Potential of computer-aided diagnosis to reduce variability in radiologists' interpretations of mammograms depicting microcalcifications (2001) Radiology, 220, pp. 787-794
Hoffmeister, J.W., Rogers, S.K., Desimio, M.P., Brem, R.F., Determining efficacy of mammographic CAD systems (2002) J Digit Imaging, 15 (SUPPL. 1), pp. 198-200
Di Maggio, C., Gambaccini, M., Gennaro, G., Digital mammography: Quality and dose control (2004) Radiol Med, 107, pp. 459-473
Haus, A. G., Yaffe, M., A cathegorical course in physics. Technical aspects in breast imaging (1993) Presented at the 79th Scientific Assembly and Annual Meeting of RSNA1993, , Radiological Society of North Americ
www. cadxmed. comhttp: //www. kodak. com/US/en/corp/pressReleases/pr20040801-01. shtmlwww. mirada-solutions. comwww. r2tech. comwww. scanis. comJong, R. A., Yaffe, M. J., Skarpathiotakis, M., Contrast-enhanced digital mammography: Initial clinical experience (2003) Radiology, 228, pp. 842-850
Amendolia, S. R., Bisogni, M. G., Bottigli, U., The CALMA project: A CAD tool in breast radiography (2001) Nucl Instrum Methods, 460, pp. 107-112
Kegelmeyer, W. P., Pruneda, J. M., Bourland, P. D., Hillis, A., Riggs, M. W., Nipper, M. L., Computer-aided mammographic screening for spiculated lesions (1994) Radiology, 191, pp. 331-337
Huo, Z., Giger, M. L., Vyborny, C. J., Analysis of spiculation in the computerized classification of mammographic masses (1995) Med Phys, 22, pp. 1569-1579
Freer, V. T., Ulissey, M. J., Screening mammograpy with computer-aided detection: Prospective study of 12, 860 patients in a community breast center (2001) Radiology, 220, pp. 781-786
Brake, G. M., Karssemeijer, N., Hendriks, J. H. C. L., Automated detection of breast carcinomas not detected in a screening program (1998) Radiology, 207, pp. 465-471
Birdwell, R. L., Ikeda, D. M., O'Shaughnessy, K. F., Sickles, E. A., Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection (2001) Radiology, 219, pp. 192-202
Burhenne, L. J., Wood, S. A., D'Orsi, C., Potential contribution of computer-aided detection to the sensitivity of srcreening mammography (2000) Radiology, 215, pp. 554-562
Metz, C. E., ROC methodology in radiological imaging (1986) Invest Radiol, 21, pp. 720-733
Green, D. N., Swets, J. A., (1966) Signal Detection Theory and Psychophysics, , John Wiley and Sons New York
www. medcalc. beHuo, Z., Giger, M. L., Vyborny, C. J., Metz, C. E., Breast cancer: Effectiveness of computer-aided diagnosis-observer study with independent database of mammograms (2002) Radiology, 224, pp. 560-568
Hays, W. L., (1963) Statistics for Psychologists, , Rinehart and Winston, Inc. Holt
Hoffmeister, J. W., Rogers, S. K., Desimio, M. P., Brem, R. F., Determining efficacy of mammographic CAD systems (2002) J Digit Imaging, 15 (SUPPL. 1), pp. 198-200
A Study On Two Different Cad Systems For Mmammography As An Aid To Radiological Diagnosis In The Search Of Microcalcification Clusters
Cusanno F, Cisbani E, Colilli S, Fratoni R, Garibaldi F, Giuliani F, Gricia M, Lucentini M, Magliozzi ML, Santarivenere F, Torrioli S, Cinti MN, Pani R, Pellegrini R, Simonetti G, Schillaci O, Del Vecchio S, Salvatore M, Majewski S, De Vincentis G, Scopinaro F * Results of clinical trials with SPEM(278 views) Nucl Instrum Methods Phys Res Sect A, 2007 Feb 1; 497(1): 46-50. Impact Factor:3.221 ViewExport to BibTeXExport to EndNote