Estimation of coronary flow reserve by Tc-99m sestamibi imaging in patients with coronary artery disease: Comparison with the results of intracoronary Doppler technique
Estimation of coronary flow reserve by Tc-99m sestamibi imaging in patients with coronary artery disease: Comparison with the results of intracoronary Doppler technique(421 views) Storto G, Cirillo P, Eufrasia Vicario ML, Pellegrino T, Sorrentino AR, Petretta M, Galasso G, De Sanctis V, Piscione F, Cuocolo A
Dept. of Biomorphol./Functional Sci., University Federico II, Via Pansini 5, 80131 Napoli, Italy
Institute of Biostructure/Bioimages, National Council of Research, Napoli, Italy
IRCCS Neuromed, Pozzilli, Italy
Department of Clinical Medicine, University Federico II, Via Pansini 5, 80131 Napoli, Italy
References: Nicolai, E., Cuocolo, A., Pace, L., Adenosine coronary vasodilatation quantitative technetium-99m methoxy isobutyl isonitrile myocardial tomography in the identification and localization of coronary artery disease (1996) J. Nucl. Cardiol., 3, pp. 9-1
Miller, D.D., Younis, L.T., Chaitman, B.R., Stratmann, H., Diagnostic accuracy of dipyridamole technetium 99m-labeled sestamibi myocardial tomography for detection of coronary artery disease (1997) J. Nucl. Cardiol., 4, pp. 18-24
Heller, G.V., Herman, S.D., Travin, M.I., Independent prognostic value of intravenous dipyridamole with technetium-99m sestamibi tomographic imaging in predicting cardiac events and cardiac-related hospital admissions (1995) J. Am. Coll. Cardiol., 26, pp. 1202-1208
Stratmann, H.G., Tamesis, B.R., Younis, L.T., Prognostic value of predischarge dipyridamole technetium-99m sestamibi myocardial tomography in medically treated patients with unstable angina (1995) Am. Heart J., 130, pp. 734-740
Garcia, E.V., Quantitative myocardial perfusion single-photon emission computed tomographic imaging: Quo vadis? (1994) J. Nucl. Cardiol., 1, pp. 83-93
Germano, G., Technical aspects of myocardial SPECT imaging (2001) J. Nucl. Med., 42, pp. 1499-1507
Klocke, F.J., Measurements of coronary flow reserve: Defining pathophysiology versus making decisions about patient care (1987) Circulation, 76, pp. 1183-1189
Hoffman, J.I., A critical view of coronary reserve (1987) Circulation, 75, pp. I6-I11
Gould, K.L., Lipscomb, K., Hamilton, G.W., Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve (1974) Am. J. Cardiol., 33, pp. 87-94
Baller, D., Notohamiprodjo, G., Gleichmann, U., Improvement in coronary flow reserve determined by positron emission tomography after 6 months of cholesterol-lowering therapy in patients with early stages of coronary atherosclerosis (1999) Circulation, 99, pp. 2871-2875
Doucette, J.W., Corl, P.D., Payne, H.M., Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity (1992) Circulation, 85, pp. 1899-1911
Aude, Y.W., Garza, L., How to prevent unnecessary coronary interventions: Identifying lesions responsible for ischemia in the cath lab (2003) Curr. Opin. Cardiol., 18, pp. 394-399
Bergmann, S.R., Herrero, P., Markham, J., Weinheimer, C.J., Walsh, M.N., Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography (1989) J. Am. Coll. Cardiol., 14, pp. 639-652
Bergmann, S.R., Fox, K.A., Rand, A.L., Quantification of regional myocardial blood flow in vivo with H2-15O (1984) Circulation, 70, pp. 724-733
Araujo, L.I., Lammertsma, A.A., Rhodes, C.G., Noninvasive quantification of regional myocardial blood flow in coronary artery disease with oxygen-15-labeled carbon dioxide inhalation and positron emission tomography (1991) Circulation, 83, pp. 875-885
Iida, H., Kanno, I., Takahashi, A., Measurement of absolute myocardial blood flow with H2-15O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume effect (1988) Circulation, 78, pp. 104-115
Taki, J., Fujino, S., Nakajima, K., Tc-99m sestamibi retention characteristics during pharmacological hyperemia in human myocardium: Comparison with coronary flow reserve measured by Doppler flowire (2001) J. Nucl. Med., 42, pp. 1457-1463
Sugihara, H., Yonekura, Y., Kataoka, K., Estimation of coronary flow reserve with the use of dynamic planar and SPECT images of Tc-99m tetrofosmin (2001) J. Nucl. Cardiol., 8, pp. 575-579
Ito, Y., Katoh, C., Noriyasu, K., Estimation of myocardial blood flow and myocardial flow reserve by 99mTc-sestamibi imaging: Comparison with the results of O-15 H2O PET (2003) Eur. J. Nucl. Med. Mol. Imaging, 30, pp. 281-287
Spinelli, L., Petretta, M., Cuocolo, A., Prediction of recovery of left ventricular dysfunction after acute myocardial infarction: Comparison between Tc-99m sestamibi cardiac tomography and low-dose dobutamine echocardiography (1999) J. Nucl. Med., 40, pp. 1683-1692
Bland, J.M., Altman, D.G., Statistical methods for assessing agreement between two methods of clinical measurement (1986) Lancet, 1, pp. 307-310
Shrout, P.E., Fleiss, J.L., Interclass correlation: Uses in assessing rater reliability (1979) Psychol. Bull., 86, pp. 420-428
Gullberg, G.T., Di Bella, E.V., Sinusas, A.J., Estimation of coronary flow reserve: Can SPECT compete with other modalities? (2001) J. Nucl. Cardiol., 8, pp. 620-625
Manchikalapudi, P., Iskandrian, A.E., How to define coronary artery stenosis severity? (2001) Catheter. Cardiovasc. Interv., 53, pp. 202-203
Sakuma, H., Kawada, N., Takeda, K., Higgins, C.B., MR measurement of coronary blood flow (1999) J. Magn. Reson. Imaging, 10, pp. 728-733
Serruys, P.W., di Mario, C., Piek, J., Prognostic value of intracoronary flow velocity and diameter stenosis in assessing the short- and long-term outcomes of balloon angioplasty (1997) Circulation, 96, pp. 3369-3377
Marcus, M.L., Wilson, R.F., White, C.W., Methods of measurement of myocardial blood flow in patients: A critical review (1987) Circulation, 76, pp. 245-253
Hoffman, J.I., Problems of coronary flow reserve (2000) Ann. Biomed. Eng., 28, pp. 884-896
Joye, J.D., Schulman, D.S., Clinical application of coronary flow reserve using an intracoronary Doppler guide wire (1997) Cardiol. Clin., 15, pp. 101-129
Kern, M.J., Deligonul, U., Tatineni, S., Intravenous adenosine: Continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease (1991) J. Am. Coll. Cardiol., 18, pp. 718-729
Rossen, J.D., Quillen, J.E., Lopez, A.G., Comparison of coronary vasodilatation with intravenous dipyridamole and adenosine (1991) J. Am. Coll. Cardiol., 18, pp. 485-491
Ogilby, J.D., Iskandrian, A.S., Untereker, W.J., Effect of intravenous adenosine infusion on myocardial perfusion and function. Hemodynamic/angiographic and scintigraphic study (1992) Circulation, 86, pp. 887-895
Masuda, D., Nohara, R., Tamaki, N., Evaluation of coronary blood flow reserve by 13N-NH3 positron emission computed tomography (PET) with dipyridamole in the treatment of hypertension with the ACE inhibitor (Cilazapril) (2000) Ann. Nucl. Med., 14, pp. 353-360
Yokoyama, I., Ohtake, T., Momomura, S., Reduced coronary flow reserve in hypercholesterolemic patients without overt coronary stenosis (1996) Circulation, 94, pp. 3232-3238
Gould, K.L., Goldstein, R.A., Mullani, N.A., Noninvasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilatation. VIII: Clinical feasibility of positron cardiac imaging without a cyclotron using generator-produced rubidium-82 (1986) J. Am. Coll. Cardiol., 7, pp. 775-789
McGinn, A.L., White, C.W., Wilson, R.F., Interstudy variability of coronary flow reserve. Influence of heart rate, arterial pressure, and ventricular preload (1990) Circulation, 81, pp. 1319-1330
Scherhag, A.W., Pfleger, S., de Mey, C., Continuous measurement of hemodynamic alterations during pharmacologic cardiovascular stress using automated impedance cardiography (1997) J. Clin. Pharmacol., 37 (SUPPL.), pp. 21S-28S
Miller, D. D., Younis, L. T., Chaitman, B. R., Stratmann, H., Diagnostic accuracy of dipyridamole technetium 99m-labeled sestamibi myocardial tomography for detection of coronary artery disease (1997) J. Nucl. Cardiol., 4, pp. 18-24
Heller, G. V., Herman, S. D., Travin, M. I., Independent prognostic value of intravenous dipyridamole with technetium-99m sestamibi tomographic imaging in predicting cardiac events and cardiac-related hospital admissions (1995) J. Am. Coll. Cardiol., 26, pp. 1202-1208
Stratmann, H. G., Tamesis, B. R., Younis, L. T., Prognostic value of predischarge dipyridamole technetium-99m sestamibi myocardial tomography in medically treated patients with unstable angina (1995) Am. Heart J., 130, pp. 734-740
Garcia, E. V., Quantitative myocardial perfusion single-photon emission computed tomographic imaging: Quo vadis? (1994) J. Nucl. Cardiol., 1, pp. 83-93
Klocke, F. J., Measurements of coronary flow reserve: Defining pathophysiology versus making decisions about patient care (1987) Circulation, 76, pp. 1183-1189
Hoffman, J. I., A critical view of coronary reserve (1987) Circulation, 75, pp. I6-I11
Gould, K. L., Lipscomb, K., Hamilton, G. W., Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve (1974) Am. J. Cardiol., 33, pp. 87-94
Doucette, J. W., Corl, P. D., Payne, H. M., Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity (1992) Circulation, 85, pp. 1899-1911
Aude, Y. W., Garza, L., How to prevent unnecessary coronary interventions: Identifying lesions responsible for ischemia in the cath lab (2003) Curr. Opin. Cardiol., 18, pp. 394-399
Bergmann, S. R., Herrero, P., Markham, J., Weinheimer, C. J., Walsh, M. N., Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography (1989) J. Am. Coll. Cardiol., 14, pp. 639-652
Bergmann, S. R., Fox, K. A., Rand, A. L., Quantification of regional myocardial blood flow in vivo with H2-15O (1984) Circulation, 70, pp. 724-733
Araujo, L. I., Lammertsma, A. A., Rhodes, C. G., Noninvasive quantification of regional myocardial blood flow in coronary artery disease with oxygen-15-labeled carbon dioxide inhalation and positron emission tomography (1991) Circulation, 83, pp. 875-885
Bland, J. M., Altman, D. G., Statistical methods for assessing agreement between two methods of clinical measurement (1986) Lancet, 1, pp. 307-310
Shrout, P. E., Fleiss, J. L., Interclass correlation: Uses in assessing rater reliability (1979) Psychol. Bull., 86, pp. 420-428
Gullberg, G. T., Di Bella, E. V., Sinusas, A. J., Estimation of coronary flow reserve: Can SPECT compete with other modalities? (2001) J. Nucl. Cardiol., 8, pp. 620-625
Serruys, P. W., di Mario, C., Piek, J., Prognostic value of intracoronary flow velocity and diameter stenosis in assessing the short- and long-term outcomes of balloon angioplasty (1997) Circulation, 96, pp. 3369-3377
Marcus, M. L., Wilson, R. F., White, C. W., Methods of measurement of myocardial blood flow in patients: A critical review (1987) Circulation, 76, pp. 245-253
Hoffman, J. I., Problems of coronary flow reserve (2000) Ann. Biomed. Eng., 28, pp. 884-896
Joye, J. D., Schulman, D. S., Clinical application of coronary flow reserve using an intracoronary Doppler guide wire (1997) Cardiol. Clin., 15, pp. 101-129
Kern, M. J., Deligonul, U., Tatineni, S., Intravenous adenosine: Continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease (1991) J. Am. Coll. Cardiol., 18, pp. 718-729
Rossen, J. D., Quillen, J. E., Lopez, A. G., Comparison of coronary vasodilatation with intravenous dipyridamole and adenosine (1991) J. Am. Coll. Cardiol., 18, pp. 485-491
Ogilby, J. D., Iskandrian, A. S., Untereker, W. J., Effect of intravenous adenosine infusion on myocardial perfusion and function. Hemodynamic/angiographic and scintigraphic study (1992) Circulation, 86, pp. 887-895
Gould, K. L., Goldstein, R. A., Mullani, N. A., Noninvasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilatation. VIII: Clinical feasibility of positron cardiac imaging without a cyclotron using generator-produced rubidium-82 (1986) J. Am. Coll. Cardiol., 7, pp. 775-789
McGinn, A. L., White, C. W., Wilson, R. F., Interstudy variability of coronary flow reserve. Influence of heart rate, arterial pressure, and ventricular preload (1990) Circulation, 81, pp. 1319-1330
Scherhag, A. W., Pfleger, S., de Mey, C., Continuous measurement of hemodynamic alterations during pharmacologic cardiovascular stress using automated impedance cardiography (1997) J. Clin. Pharmacol., 37 (SUPPL.), pp. 21S-28S
Estimation of coronary flow reserve by Tc-99m sestamibi imaging in patients with coronary artery disease: Comparison with the results of intracoronary Doppler technique
Estimation of coronary flow reserve by Tc-99m sestamibi imaging in patients with coronary artery disease: Comparison with the results of intracoronary Doppler technique
Estimation of coronary flow reserve by Tc-99m sestamibi imaging in patients with coronary artery disease: Comparison with the results of intracoronary Doppler technique
Hesse B, Tagil K, Cuocolo A, Anagnostopoulos C, Bardies M, Bax J, Bengel F, Busemann Sokole E, Davies G, Dondi M, Edenbrandt L, Franken P, Kjaer A, Knuuti J, Lassmann M, Ljungberg M, Marcassa C, Marie PY, Mckiddie F, O'connor M, Prvuolovich E, Underwood R * 3. 0 T perfusion MR imaging(692 views) Rivista Di Neuroradiologia (ISSN: 1120-9976), 2004; 17(6): 807-812. Impact Factor:0.023 ViewExport to BibTeXExport to EndNote