Department of Clinical Medicine, Cardiovascular and Immunological Sciences, University of Naples Federico II, Naples, Italy
Department of Biomorphological and Functional Sciences, University of Naples Federico II, Via Pansini 5, 80131 Naples, Italy
Institute of Biostructures and Bioimages, National Council of Research, Naples, Italy
References: Cuocolo, A., Petretta, M., Acampa, W., de Falco, T., Gated SPECT myocardial perfusion imaging: the further improvements of an excellent tool (2010) Q J Nucl Med Mol Imaging, 54, pp. 129-144. , This article details the improvements of gated SPECT myocardial perfusion imagin
Iskandrian, A.E., Garcia, E.V., Faber, T., Mahmarian, J.J., Automated assessment of serial SPECT myocardial perfusion images (2009) J Nucl Cardiol, 16, pp. 6-9
Mahmarian, J.J., Shaw, L.J., Filipchuk, N.G., A multinational study to establish the value of early adenosine technetium-99 m sestamibi myocardial perfusion imaging in identifying a low-risk group for early hospital discharge after acute myocardial infarction (2006) J Am Coll Cardiol, 48, pp. 2448-2457
Trobaugh, G.B., Wackers, F., Sokole, E.B., Thallium-201 myocardial imaging: an interinstitutional study of observer variability (1977) J Nucl Med, 19, pp. 359-363
Wackers, F.J., Science, art, and artifacts: how important is quantification for the practicing physician interpreting myocardial perfusion studies? (1994) J Nucl Cardiol, 1, pp. S109-S117
Watson, D.D., Campbell, N.P., Read, E.K., Spatial and temporal quantitation of plane thallium myocardial images (1981) J Nucl Med, 22, pp. 577-584
Garcia, E., Maddahi, J., Berman, D., Waxman, A., Space/time quantitation of thallium-201 myocardial scintigraphy (1981) J Nucl Med, 22, pp. 309-317
Garcia, E.V., van Train, K., Maddahi, J., Quantification of rotational thallium-201 myocardial tomography (1985) J Nucl Med, 26, pp. 17-26
DePasquale, E., Nody, A., DePuey, G., Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease (1988) Circulation, 77, pp. 316-327
Faber, T.L., Santana, C.A., Garcia, E.V., Three-dimensional fusion of coronary arteries with myocardial perfusion distributions: clinical validation (2004) J Nucl Med, 45, pp. 745-753
Rispler, S., Keidar, Z., Ghersin, E., Integrated single-photon emission computed tomography and computed tomography coronary angiography for the assessment of hemodynamically significant coronary artery lesions (2007) J Am Coll Cardiol, 49, pp. 1059-1067
Germano, G., Kavanagh, P.B., Slomka, P.J., Quantitation in gated perfusion SPECT imaging: the Cedars-Sinai approach (2007) J Nucl Cardiol, 14, pp. 433-454. , This article describes in detail the quantitative perfusion SPECT (QPS) and quantitative gated SPECT (QGS) approaches developed at the Cedars-Sinai Medical Center
Slomka, P.J., Nishina, H., Berman, D.S., Automated quantification of myocardial perfusion SPECT using simplified normal limits (2005) J Nucl Cardiol, 12, pp. 66-77
Klocke, F.J., Baird, M.G., Lorell, B.H., ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging-executive summary-a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to revise the 1995 guidelines for the clinical use of cardiac radionuclide imaging) (2003) J Am Coll Cardiol, 42, pp. 1318-1333
Hachamovitch, R., Hayes, S.W., Friedman, J.D., Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography (2003) Circulation, 107, pp. 2900-2907
Berman, D.S., Kang, X.P., Hayes, S.W., Adenosine myocardial perfusion single-photon emission computed tomography in women compared with men-impact of diabetes mellitus on incremental prognostic value and effect on patient management (2003) J Am Coll Cardiol, 41, pp. 1125-1133
Berman, D., Abidov, A., Kang, X., Prognostic validation of a 17-segment score derived from a 20-segment score for myocardial perfusion SPECT interpretation (2004) J Nucl Cardiol, 11, pp. 414-423
Acampa, W., Caprio, M.G., Nicolai, E., Assessment of poststress left ventricular ejection fraction by gated SPECT: comparison with equilibrium radionuclide angiocardiography (2010) Eur J Nucl Med Mol Imaging, 37, pp. 349-456
Watson, D.D., Smith II, W.H., The role of quantitation in clinical nuclear cardiology: the University of Virginia approach (2007) J Nucl Cardiol, 14, pp. 466-482. , This article describes the VQuant program for single-photon emission computed tomography myocardial perfusion images developed at the University of Virginia Health System
Ficaro, E.P., Lee, B.C., Kritzman, J.N., Corbett, J.R., Corridor4DM: the Michigan method for quantitative nuclear cardiology (2007) J Nucl Cardiol, 14, pp. 455-465. , This article describes the Corridor4DM (4DM), a quantitative software application providing automated processing, analysis, and reporting of myocardial perfusion and function from cardiac emission computed tomography studies developed at the University of Michigan Medical Center
DePuey, E.G., Corbett, J.R., Friedman, J.D., Imaging guidelines for nuclear cardiology procedures (2006) J Nucl Cardiol, 13, pp. e21-e171
Liu, Y.H., Quantification of nuclear cardiac images: the Yale approach (2007) J Nucl Cardiol, 14, pp. 483-491. , This review describes the methodology and validation of the approach at Yale University for quantification of cardiac images and discusses future directions for molecular targeted imaging
Liu, Y.H., Sinusas, A.J., DeMan, P., Quantification of SPECT myocardial perfusion images: methodology and validation of the Yale-CQ method (1999) J Nucl Cardiol, 6, pp. 190-204
Mahmarian, J.J., Moye, L.A., Verani, M.S., High reproducibility of myocardial perfusion defects in patients undergoing serial exercise thallium-201 tomography (1995) Am J Cardiol, 75, pp. 1116-1169
Shaw, L.J., Berman, D.S., Maron, D.J., Optimal medical therapy with or without percutaneous coronary intervention to reduce ischemic burden: Results from the Clinical Outcomes Utilizing Revascularization and Aggressive Drug Evaluation (COURAGE) trial nuclear substudy (2008) Circulation, 117, pp. 1283-1291. , This trial demonstrated that adding coronary intervention to optimal medical therapy resulted in greater reduction in ischemia compared with medical therapy alone and suggested a treatment target of at least 5% ischemia reduction with medical therapy with or without revascularization
Dangas, G., Stone, G.W., Weinberg, M.D., Contemporary outcomes of rescue percutaneous coronary intervention for acute myocardial infarction: Comparison with primary angioplasty and the role of distal protection devices (EMERALD trial) (2008) Am Heart J, 155, pp. 1090-1096
Cuberas-Borrós, G., Aguadé-Bruix, S., Boronat-de Ferrater, M., Normal myocardial perfusion SPECT database for the Spanish population (2010) Rev Esp Cardiol, 63, pp. 934-942
Nakajima, K., Okuda, K., Kawano, M., The importance of population-specific normal database for quantification of myocardial ischemia: comparison between Japanese 360 and 180-degree databases and a US database (2009) J Nucl Cardiol, 16, pp. 422-430
Nakajima, K., Matsuo, S., Kawano, M., The validity of multi-center common normal database for identifying myocardial ischemia: Japanese Society of Nuclear Medicine working group database (2010) Ann Nucl Med, 24, pp. 99-105
Heller, G.V., Links, J., Bateman, T.M., American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: attenuation correction of myocardial perfusion SPECT scintigraphy (2004) J Nucl Cardiol, 11, pp. 229-230
Hendel, R.C., Merman, D.S., Cullom, S.J., Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging (1999) Circulation, 99, pp. 2742-2749
Thompson, R.C., Heller, G.V., Johnson, L.L., Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass index (2005) J Nucl Cardiol, 12, pp. 195-202
Masood, Y., Liu, Y.H., Depuey, G., Clinical validation of SPECT attenuation correction using x-ray computed tomography-derived attenuation maps: multicenter clinical trial with angiographic correlation (2005) J Nucl Cardiol, 12, pp. 676-686
Tragardh, E., Sjostrand, K., Jakobsson, D., Edenbrandt, L., Small average differences in attenuation corrected images between men and women in myocardial perfusion scintigraphy: a novel normal stress database (2011) BMC Med Imaging, 11, p. 18
Okuda, K., Nakajima, K., Hosoya, T., Quantification of myocardial perfusion SPECT using freeware package (cardioBull) (2011) Ann Nucl Med, 25, pp. 571-579. , This study evaluates the diagnostic performance of the detection of coronary artery disease with newly developed software for automatic quantification of myocardial perfusion imaging
Soneson, H., Hedeer, F., Arévalo, C., Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard (2011) J Nucl Cardiol, 18, pp. 874-885. , This study describes and validates a new left ventricular segmentation algorithm in gated SPECT by using cardiac magnetic resonance for optimization
Petretta, M., Soricelli, A., Storto, G., Cuocolo, A., Assessment of coronary flow reserve using single photon emission computed tomography with technetium 99m-labeled tracers (2008) J Nucl Cardiol, 15, pp. 456-465