In Vitro and In Vivo Assessment of Nonionic Iodinated Radiographic Molecules as Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Tumor Perfusion Agents
In Vitro and In Vivo Assessment of Nonionic Iodinated Radiographic Molecules as Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Tumor Perfusion Agents(346 views) Longo DL, Michelotti F, Consolino L, Bardini P, Digilio G, Xiao G, Sun PZ, Aime S
From the *Istituto di Biostrutture e Bioimmagini - CNR, Molecular Biotechnology Center, and daggerDepartment of Molecular Biotechnology and Health Sciences, Molecular Imaging Center, University of Turin, Turin; double daggerDepartment of Science and Technological Innovation, Universita del Piemonte Orientale A. Avogadro, Alessandria, Italy; section signDepartment of Mathematics and Statistics, Hanshan Normal University, Guangdong, China; parallelAthinoula A. Martinos Center for Biomedical Imaging, Charlestown; Department of Radiology, Massachusetts General Hospital; and Harvard Medical School, Boston, MA.,
Universita degli Studi di Torino
References: Kramer, R.A., Janetos, G.P., Peristein, G., An approach to contrast enhancement in computed tomography of the brain (1975) Radiology., 116, pp. 641-64
Miles, K.A., Functional computed tomography in oncology (2002) Eur J Cancer., 38, pp. 2079-2084
Dugdale, P.E., Miles, K.A., Bunce, I., CT measurement of perfusion and permeability within lymphoma masses and its ability to assess grade, activity, and chemotherapeutic response (1999) J Comput Assist Tomogr., 23, pp. 540-547
Hasebroock, K.M., Serkova, N.J., Toxicity of MRI and CT contrast agents (2009) Expert Opin Drug Metab Toxicol., 5, pp. 403-416
Aime, S., Nano, R., Grandi, M., A new class of contrast agents for magnetic resonance imaging based on selective reduction of water-T2 by chemical exchange (1988) Invest Radiol., 23, pp. S267-S270
Aime, S., Calabi, L., Biondi, L., Iopamidol: Exploring the potential use of awellestablished x-ray contrast agent for MRI (2005) Magn Reson Med., 53, pp. 830-834
Ward, K.M., Aletras, A.H., Balaban, R.S., A new class of contrast agents forMRI based on proton chemical exchange dependent saturation transfer (CEST) (2000) J Magn Reson., 143, pp. 79-87
Van Zijl, P.C., Yadav, N.N., Chemical exchange saturation transfer (CEST): What is in a name and what isn't? (2011) Magn Reson Med., 65, pp. 927-948
Vinogradov, E., Sherry, A.D., Lenkinski, R.E., CEST: From basic principles to applications, challenges and opportunities (2013) J Magn Reson., 229, pp. 155-172
Liu, G., Song, X., Chan, K.W., Nuts and bolts of chemical exchange saturation transfer MRI (2013) NMR Biomed., 26, pp. 810-828
Kogan, F., Hariharan, H., Reddy, R., Chemical exchange saturation transfer (CEST) imaging: Description of technique and potential clinical applications (2013) Curr Radiol Rep., 1, pp. 102-114
Castelli, D.D., Terreno, E., Longo, D., Nanoparticle-based chemical exchange saturation transfer (CEST) agents (2013) NMR Biomed., 26, pp. 839-849
Terreno, E., Castelli, D.D., Aime, S., Encoding the frequency dependence inMRI contrast media: The emerging class of CEST agents (2010) Contrast Media Mol Imaging., 5, pp. 78-98
Longo, D.L., Dastrù, W., Digilio, G., Iopamidol as a responsive MRI-chemical exchange saturation transfer contrast agent for pH mapping of kidneys: In vivo studies in mice at 7 T (2011) Magn Reson Med., 65, pp. 202-211
Longo, D.L., Busato, A., Lanzardo, S., Imaging the pH evolution of an acute kidney injury model by means of iopamidol, a MRI-CEST pH-responsive contrast agent (2013) Magn Reson Med., 70, pp. 859-864
Chen, L.Q., Howison, C.M., Jeffery, J.J., Evaluations of extracellular pH within in vivo tumors using acidoCEST MRI (2014) Magn Reson Med., 72, pp. 1408-1417
Chen, L.Q., Randtke, E.A., Jones, K.M., Evaluations of tumor acidosis within in vivo tumor models using parametric maps generated with acidoCEST MRI (2015) Mol Imaging Biol., 17, pp. 488-496
Jones, K.M., Randtke, E.A., Howison, C.M., Measuring extracellular pH in a lung fibrosis model with acidoCEST MRI (2015) Mol Imaging Biol., 17, pp. 177-184
Longo, D.L., Sun, P.Z., Consolino, L., A general MRI-CEST ratiometric approach for pH imaging: Demonstration of in vivo pH mapping with iobitridol (2014) J Am Chem Soc., 136, pp. 14333-14336
Müller-Lutz, A., Khalil, N., Schmitt, B., Pilot study of iopamidol-based quantitative pH imaging on a clinical 3T MR scanner (2014) MAGMA, 27, pp. 477-485
Chan, K.W., McMahon, M.T., Kato, Y., Natural D-glucose as a biodegradable MRI contrast agent for detecting cancer (2012) Magn Reson Med., 68, pp. 1764-1773
Nasrallah, F.A., Pages, G., Kuchel, P.W., Imaging brain deoxyglucose uptake and 1metabolism by glucoCEST MRI (2013) J Cereb Blood Flow Metab., 33, pp. 1270-1278
Rivlin, M., Horev, J., Tsarfaty, I., Molecular imaging of tumors and metastases using chemical exchange saturation transfer (CEST) MRI (2013) Sci Rep., 3, p. 3045
Delli Castelli, D., Ferrauto, G., Cutrin, J.C., In vivo maps of extracellular pH in murine melanoma by CEST-MRI (2014) Magn Reson Med., 71, pp. 326-332
Sheth, V.R., Li, Y., Chen, L.Q., Measuring in vivo tumor pHe with CEST-FISP MRI (2012) Magn Reson Med., 67, pp. 760-768
Nanni, P., De Giovanni, C., Lollini, P.L., TS/A: A new metastasizing cell line from a BALB/c spontaneous mammary adenocarcinoma (1983) Clin Exp Metastasis., 1, pp. 373-380
Terreno, E., Stancanello, J., Longo, D., Methods for an improved detection of the MRI-CEST effect (2009) Contrast Media Mol Imaging., 4, pp. 237-247
McMahon, M.T., Gilad, A.A., Zhou, J., Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): Ph calibration for poly-L-lysine and a starburst dendrimer (2006) Magn Reson Med., 55, pp. 836-847
Nishino, M., Jagannathan, J.P., Ramaiya, N.H., Revised RECIST guideline version 1.1: What oncologists want to know and what radiologists need to know (2010) AJR Am J Roentgenol., 195, pp. 281-289
Gwyther, S.J., Schwartz, L.H., How to assess anti-tumour efficacy by imaging techniques (2008) Eur J Cancer., 44, pp. 39-45
Jiang, T., Kambadakone, A., Kulkarni, N.M., Monitoring response to antiangiogenic treatment and predicting outcomes in advanced hepatocellular carcinoma using image biomarkers, CT perfusion, tumor density, and tumor size (RECIST) (2012) Invest Radiol., 47, pp. 11-17
Reagan-Shaw, S., Nihal, M., Ahmad, N., Dose translation from animal to human studies revisited (2008) FASEB J., 22, pp. 659-661
Obeid, L., Deman, P., Tessier, A., Absolute perfusion measurements and associated iodinated contrast agent time course in brain metastasis: A study for contrastenhanced radiotherapy (2014) J Cereb Blood Flow Metab., 34, pp. 638-645
O'Connor, J.P., Rose, C.J., Waterton, J.C., Imaging intratumor heterogeneity: Role in therapy response, resistance, and clinical outcome (2015) Clin Cancer Res., 21, pp. 249-257
Miles, K.A., Lee, T.Y., Goh, V., Current status and guidelines for the assessment of tumour vascular support with dynamic contrast-enhanced computed tomography (2012) Eur Radiol., 22, pp. 1430-1441
Van Zijl, P.C., Jones, C.K., Ren, J., MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST) (2007) Proc Natl Acad Sci U S A., 104, pp. 4359-4364
Ling, W., Regatte, R.R., Navon, G., Assessment of glycosaminoglycan concentration in vivo by chemical exchange-dependent saturation transfer (gagCEST) (2008) Proc Natl Acad Sci U S A., 105, pp. 2266-2270
Zhou, J., Wilson, D.A., Sun, P.Z., Quantitative description of proton exchange processes between water and endogenous and exogenous agents forWEX, CEST, and APT experiments (2004) Magn Reson Med., 51, pp. 945-952
Zaiss, M., Schmitt, B., Bachert, P., Quantitative separation of CESTeffect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectra (2011) J Magn Reson., 211, pp. 149-155
Yang, X., Song, X., Li, Y., Salicylic acid and analogues as diaCEST MRI contrast agents with highly shifted exchangeable proton frequencies (2013) Angew Chem Int Ed Engl., 52, pp. 8116-8119
Smolinske, S.C., Hall, A.H., Vandenberg, S.A., Toxic effects of nonsteroidal antiinflammatory drugs in overdose (1990) An Overview of Recent Evidence on Clinical Effects and Dose-response Relationships. Drug Saf., 5, pp. 252-274
Felder, E., Pitrè, D., Tirone, P., Radiopaque contrast media (1977) XLIV-Preclinical Studies with A New Nonionic Contrast Agent. Farmaco Sci., 32, pp. 835-844
Pitrè, D., Felder, E., Development, chemistry, and physical properties of iopamidol and its analogues (1980) Invest Radiol., 15, pp. S301-S309
Sun, P.Z., Van Zijl, P.C., Zhou, J., Optimization of the irradiation power in chemical exchange dependent saturation transfer experiments (2005) J Magn Reson., 175, pp. 193-200
Sun, P.Z., Longo, D.L., Hu, W., Quantification of iopamidol multi-site chemical exchange properties for ratiometric chemical exchange saturation transfer (CEST) imaging of pH (2014) Phys Med Biol., 59, pp. 4493-4504
Shah, T., Lu, L., Dell, K.M., CEST-FISP: A novel technique for rapid chemical exchange saturation transfer MRI at 7 T (2011) Magn Reson Med., 65, pp. 432-437
Zaiss, M., Xu, J., Goerke, S., Inverse Z-spectrum analysis for spillover-, MT-, and T1-corrected steady-state pulsed CEST-MRI - Application to pH-weighted MRI of acute stroke (2014) NMR Biomed., 27, pp. 240-252
Sun, P.Z., Cheung, J.S., Wang, E., Fast multislice pH-weighted chemical exchange saturation transfer (CEST) MRI with Unevenly segmented RF irradiation (2011) Magn Reson Med., 65, pp. 588-594
Zhu, H., Jones, C.K., Van Zijl, P.C., Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain (2010) Magn Reson Med., 64, pp. 638-644
Zaiss, M., Zu, Z., Xu, J., A combined analytical solution for chemical exchange saturation transfer and semi-solid magnetization transfer (2015) NMR Biomed., 28, pp. 217-230
Wu, R., Longo, D.L., Aime, S., Quantitative description of radiofrequency (RF) power-based ratiometric chemical exchange saturation transfer (CEST) pH imaging (2015) NMR Biomed., 28, pp. 555-565
SantosMello, R., Callisen, H., Winter, J., Radiation dose enhancement in tumors with iodine (1983) Med Phys., 10, pp. 75-78
Adam, J.F., Biston, M.C., Joubert, A., Enhanced delivery of iodine for synchrotron stereotactic radiotherapy by means of intracarotid injection and blood-brain barrier disruption: Quantitative iodine biodistribution studies and associated dosimetry (2005) Int J Radiat Oncol Biol Phys., 61, pp. 1173-1182
In Vitro and In Vivo Assessment of Nonionic Iodinated Radiographic Molecules as Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Tumor Perfusion Agents
In Vitro and In Vivo Assessment of Nonionic Iodinated Radiographic Molecules as Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Tumor Perfusion Agents
In Vitro and In Vivo Assessment of Nonionic Iodinated Radiographic Molecules as Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Tumor Perfusion Agents
Malvindi MA, Greco A, Conversano F, Figuerola A, Corti M, Bonora M, Lascialfari A, Doumari HA, Moscardini M, Cingolani R, Gigli G, Casciaro S, Pellegrino T, Ragusa A * MR Contrast Agents(292 views) Small Animal Imaging, 2011 Jul 8; 21(13): 2548-2555. Impact Factor:1.784 ViewExport to BibTeXExport to EndNote