Buffalo Neuroimaging Analysis Center, Department of Neurology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, New York, USA.
Institute of Biostructure and Bioimaging, National Research Council of Italy, Rome, Italy.
Center for Biomedical Imaging at Clinical Translational Science Institute, University at Buffalo, State University of New York, Buffalo, New York, USA. Electronic address: rzivadinov@bnac.net.
References: American Institute of Ultrasound in Medicine, American College of Radiology, Society of Radiologists in Ultrasound, AIUM practice guideline for the performance of peripheral arterial ultrasound examinations using color and spectral Doppler imaging (2014) J Ultrasound Med, 33, pp. 1111-112
Badano, L.P., Dall'Armellina, E., Monaghan, M.J., Pepi, M., Baldassi, M., Cinello, M., Fioretti, P.M., Real-time three-dimensional echocardiography: Technological gadget or clinical tool? (2007) J Cardiovasc Med (Hagerstown), 8, pp. 144-162
Breen, P.P., Galvin, O., Grace, P.A., Laighin, G.O., Doppler ultrasound measurements of venous return in the popliteal vein (2007) Conf Proc IEEE Eng Med Biol Soc, 2007, pp. 978-981
Cejas, C., Cisneros, L.F., Lagos, R., Zuk, C., Ameriso, S.F., Internal jugular vein valve incompetence is highly prevalent in transient global amnesia (2010) Stroke, 41, pp. 67-71
Chambers, B., Chambers, J., Churilov, L., Cameron, H., Macdonell, R., Internal jugular and vertebral vein volume flow in patients with clinically isolated syndrome or mild multiple sclerosis and healthy controls: Results from a prospective sonographer-blinded study (2014) Phlebology, 29, pp. 528-535
Chi, H.Y., Lin, C.S., Hsu, M.H., Chan, P.C., Hu, H.H., Chronic influences of obstructive sleep apnea on cerebral venous flow (2015) J Ultrasound Med, 34, pp. 2043-2048
Chuang, Y.M., Hu, H.H., Cough headache and thoracic inlet valvular competence in uremia (2005) Eur Neurol, 53, pp. 78-80
Chung, C.P., Chao, A.C., Hsu, H.Y., Lin, S.J., Hu, H.H., Decreased jugular venous distensibility in migraine (2010) Ultrasound Med Biol, 36, pp. 11-16
Ciuti, G., Righi, D., Forzoni, L., Fabbri, A., Pignone, A.M., Differences between internal jugular vein and vertebral vein flow examined in real time with the use of multigate ultrasound color Doppler (2013) AJNR Am J Neuroradiol, 34, pp. 2000-2004
Constant, J., Using internal jugular pulsations as a manometer for right atrial pressure measurements (2000) Cardiology, 93, pp. 26-30
Di Berardino, F., Alpini, D.C., Bavera, P.M., Cecconi, P., Farabola, M., Mattei, V., Ambrosetti, U., Cesarani, A., Chronic cerebrospinal venous insufficiency in Meniere disease (2015) Phlebology, 30, pp. 274-279
Ficial, B., Finnemore, A.E., Cox, D.J., Broadhouse, K.M., Price, A.N., Durighel, G., Ekitzidou, G., Groves, A.M., Validation study of the accuracy of echocardiographic measurements of systemic blood flow volume in newborn infants (2013) J Am Soc Echocardiogr, 26, pp. 1365-1371
Gerada, M., Struijk, P.C., Stewart, P.A., Guerriero, S., Melis, G.B., Wladimiroff, J.W., Comparison between color Doppler cineloop- and conventional spectral Doppler-derived maximum velocity and flow in the umbilical vein (2006) Ultrasound Obstet Gynecol, 28, pp. 156-161
Gill, R.W., Measurement of blood flow by ultrasound: Accuracy and sources of error (1985) Ultrasound Med Biol, 11, pp. 625-641
Jakimovski, D., Marr, K., Mancini, M., Caprio, M.G., Gandhi, S., Bergsland, N., Paunkoski, I., Zivadinov, R., Global and regional brain atrophy is associated with low or retrograde facial vein flow in multiple sclerosis (2017) Veins Lymphatics, 6
Lagana, M.M., Di Rienzo, M., Rizzo, F., Ricci, C., D'Onofrio, S., Forzoni, L., Cecconi, P., Cardiac, respiratory and postural influences on venous return of internal jugular and vertebral veins (2017) Ultrasound Med Biol, 43, pp. 1195-1204
Lin, S.K., Chang, Y.J., Yang, F.Y., Hemodynamics of the internal jugular vein: An ultrasonographic study (2009) Tzu Chi Med J, 21, pp. 317-322
Liu, M., Xu, H., Wang, Y., Zhong, Y., Xia, S., Utriainen, D., Wang, T., Haacke, E.M., Patterns of chronic venous insufficiency in the dural sinuses and extracranial draining veins and their relationship with white matter hyperintensities for patients with Parkinson's disease (2015) J Vasc Surg, 61, pp. 1511-1520. , e1
Monti, L., Menci, E., Ulivelli, M., Cerase, A., Bartalini, S., Piu, P., Marotti, N., Venturi, C., Quantitative colour Doppler sonography evaluation of cerebral venous outflow: A comparative study between patients with multiple sclerosis and controls (2011) PLoS ONE, 6. , e25012
Nagdev, A.D., Merchant, R.C., Tirado-Gonzalez, A., Sisson, C.A., Murphy, M.C., Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure (2010) Ann Emerg Med, 55, pp. 290-295
Nakamura, K., Qian, K., Ando, T., Inokuchi, R., Doi, K., Kobayashi, E., Sakuma, I., Yahagi, N., Cardiac variation of internal jugular vein for the evaluation of hemodynamics (2016) Ultrasound Med Biol, 42, pp. 1764-1770
Naqvi, J., Yap, K.H., Ahmad, G., Ghosh, J., Transcranial Doppler ultrasound: A review of the physical principles and major applications in critical care (2013) Int J Vasc Med, 2013. , 629378
Nicolaides, A.N., Morovic, S., Menegatti, E., Viselner, G., Zamboni, P., Screening for chronic cerebrospinal venous insufficiency (CCSVI) using ultrasound: Recommendations for a protocol (2011) Funct Neurol, 26, pp. 229-248
Ozen, O., Unal, O., Avcu, S., Flow volumes of internal jugular veins are significantly reduced in patients with cerebral venous sinus thrombosis (2014) Curr Neurovasc Res, 11, pp. 75-82
Pinter, S.Z., Rubin, J.M., Kripfgans, O.D., Novelli, P.M., Vargas-Vila, M., Hall, A.L., Fowlkes, J.B., Volumetric blood flow in transjugular intrahepatic portosystemic shunt revision using 3-dimensional Doppler sonography (2015) J Ultrasound Med, 34, pp. 257-266
Schreiber, S.J., Lurtzing, F., Gotze, R., Doepp, F., Klingebiel, R., Valdueza, J.M., Extrajugular pathways of human cerebral venous blood drainage assessed by duplex ultrasound (2003) J Appl Physiol, 94, pp. 1802-1805
Sisini, F., Gianesini, S., Menegatti, E., Taibi, A., Tessari, M., Di Domenico, G., Malagoni, A.M., Gambaccini, M., On the consistency of flow rate color Doppler assessment for the internal jugular vein (2014) Veins Lymphatics, 3
Sisini, F., Tessari, M., Gadda, G., Di Domenico, G., Taibi, A., Menegatti, E., Gambaccini, M., Zamboni, P., An ultrasonographic technique to assess the jugular venous pulse: A proof of concept (2015) Ultrasound Med Biol, 41, pp. 1334-1341
Stankovic, Z., Csatari, Z., Deibert, P., Euringer, W., Blanke, P., Kreisel, W., Abdullah Zadeh, Z., Markl, M., Normal and altered three-dimensional portal venous hemodynamics in patients with liver cirrhosis (2012) Radiology, 262, pp. 862-873
Utriainen, D., Feng, W., Elias, S., Latif, Z., Hubbard, D., Haacke, E.M., Using magnetic resonance imaging as a means to study chronic cerebral spinal venous insufficiency in multiple sclerosis patients (2012) Tech Vasc Interv Radiol, 15, pp. 101-112
von Ramm, O.T., Smith, S.W., Real time volumetric ultrasound imaging system (1990) J Digit Imaging, 3, pp. 261-266
Van Canneyt, K., Swillens, A., Lovstakken, L., Antiga, L., Verdonck, P., Segers, P., The accuracy of ultrasound volume flow measurements in the complex flow setting of a forearm vascular access (2013) J Vasc Access, 14, pp. 281-290
Vicenzini, E., Pro, S., Sirimarco, G., Pulitano, P., Mecarelli, O., Lenzi, G.L., Di Piero, V., Three dimensional imaging of carotid arteries: Advantages and pitfalls of ultrasound investigations (2012) Perspect Med, 1, pp. 82-85
Yeoh, T.Y., Venkatraghavan, L., Fisher, J.A., Meineri, M., Internal jugular vein blood flow in the upright position during external compression and increased central venous pressure: An ultrasound study in healthy volunteers (2017) Can J Anaesth, 64, pp. 854-859
Zamboni, P., Why current Doppler ultrasound methodology is inaccurate in assessing cerebral venous return: The alternative of the ultrasonic jugular venous pulse (2016) Behav Neurol, 2016. , 7082856
Zamboni, P., Sisini, F., Menegatti, E., Taibi, A., Malagoni, A.M., Morovic, S., Gambaccini, M., An ultrasound model to calculate the brain blood outflow through collateral vessels: A pilot study (2013) BMC Neurol, 13, p. 81
Zivadinov, R., Ramanathan, M., Dolic, K., Marr, K., Karmon, Y., Siddiqui, A.H., Benedict, R.H., Weinstock-Guttman, B., Chronic cerebrospinal venous insufficiency in multiple sclerosis: Diagnostic, pathogenetic, clinical and treatment perspectives (2011) Expert Rev Neurother, 11, pp. 1277-1294
Zivadinov, R., Bastianello, S., Dake, M.D., Ferral, H., Haacke, E.M., Haskal, Z.J., Hubbard, D., Zamboni, P., International Society for Neurovascular Disease. Recommendations for multimodal noninvasive and invasive screening for detection of extracranial venous abnormalities indicative of chronic cerebrospinal venous insufficiency: A position statement of the International Society for Neurovascular Disease (2014) J Vasc Interv Radiol, 25, pp. 1785-1794. , e17
Jugular Venous Flow Quantification Using Doppler Sonography
Hesse B, Tagil K, Cuocolo A, Anagnostopoulos C, Bardies M, Bax J, Bengel F, Busemann Sokole E, Davies G, Dondi M, Edenbrandt L, Franken P, Kjaer A, Knuuti J, Lassmann M, Ljungberg M, Marcassa C, Marie PY, Mckiddie F, O'connor M, Prvuolovich E, Underwood R * 3. 0 T perfusion MR imaging(730 views) Rivista Di Neuroradiologia (ISSN: 1120-9976), 2004; 17(6): 807-812. Impact Factor:0.023 ViewExport to BibTeXExport to EndNote