Use of ultrasound shear wave to measure muscle stiffness in children with cerebral palsy(263 views) Vola EA, Albano M, Di Luise C, Servodidio V, Sansone M, Russo S, Corrado B, Servodio Iammarrone C, Caprio MG, Vallone G
Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy. elena.a.vola@gmail.com.
Department of Public Health, University of Naples Federico II, Naples, Italy.
Department of Electrical Engineering and Information Technology (DIETI), University of Naples Federico II, Naples, Italy.
Institute of Biostructure and Bioimaging, National Research Council of Italy, Naples, Italy.
References: Ozmen, M., Caliskan, M., Apak, S., Gokcay, G., 8 years clinical experience in cerebral palsy (1993) J Trop Pediatr, 39, pp. 52-5
Lance, J., Spasticity: disorders motor control (1980) Symposium synopsis, , Feldman RG, Young RP, Koella WP, (eds), Year Book Medical Publishers, Miami, FL
Haas, B., Bergstrom, E., Jamous, A., Bennie, A., The inter rater reliability of the original and of the modified ashworth scale for the assessment of spasticity in patients with spinal cord injury (1996) Spinal Cord, 34, pp. 560-564
Mentiplay, B.F., Perraton, L.G., Bower, K.J., Assessment of lower limb muscle strength and power using hand-held and fixed dynamometry: a reliability and validity study (2015) PLoS One, 10 (10). , PID: 26509265
Stark, T., Walker, B., Phillips, J.K., Fejer, R., Beck, R., Hand-held dynamometry correlation with the gold standard isokinetic dynamometry: a systematic review (2011) PM & R, 3 (5), pp. 472-479
Kolber, M.J., Cleland, J.A., Strength testing using hand-held dynamometry (2005) Phys Therapy Rev, 10 (2), pp. 99-112
Choi, Y.J., Ultrasound elastography for evaluation of cervical lymph nodes (2015) Ultrasonography, 34 (3), pp. 157-164. , PID: 25827473
Ryu, J., Jeong, W.K., Current status of musculoskeletal application of shear wave elastography (2017) Ultrasonography, 36, pp. 185-197. , PID: 28292005
Kim, S.J., Park, H.J., Lee, S.Y., Usefulness of strain elastography of the musculoskeletal system (2016) Ultrasonography, 35, pp. 104-109. , PID: 26810195
Arda, K., Ciledag, N., Aktas, E., Aribas, B.K., Kose, K., Quantitative assessment of normal soft-tissue elasticity using shear-wave ultrasound elastography (2011) AJR Am J Roentgenol, 197, pp. 532-536. , PID: 21862792
Gennisson, J.L., Deffieux, T., Fink, M., Tanter, M., Ultrasound elastography: principles and techniques (2013) Diagn Interv Imaging, 94, pp. 487-495. , PID: 23619292
Bamber, J., Cosgrove, D., Dietrich, C.F., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Piscaglia, F., EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 1: Basic principles and technology (2013) Ultraschall Med, 34, pp. 169-184. , PID: 23558397
Mulabecirovic, A., Mjelle, A.B., Gilja, O.H., Vesterhus, M., Havre, R.F., Repeatability of shear wave elastography in liver fibrosis phantoms—evaluation of five different systems (2018) PLoS One, 13 (1)
Park, D.-S., Kwon, D.R., Park, G.-Y., Lee, M.Y., Therapeutic effect of extracorporeal shock wave therapy according to treatment session on gastrocnemius muscle spasticity in children with spastic cerebral palsy: a pilot study (2015) Ann Rehabilit Med, 39 (6), pp. 914-921
Prado, L.G., Makarenko, I., Andresen, C., Kruger, M., Opitz, C.A., Linke, W.A., Isoform diversity of giant proteins in relation to passive and active contractile properties of rabbit skeletal muscles (2005) J Gen Physiol, 126, pp. 461-480. , PID: 16230467
Chen, X., Li, Y., Role of matrix metalloproteinases in skeletal muscle: migration, differentiation, regeneration and fibrosis (2009) Cell Adhes Migr, 3, pp. 337-341
Smith, L.R., Lee, K.S., Ward, S.R., Chambers, H.G., Lieber, R.L., Hamstring contractures in children with spastic cerebral palsy result from a stiffer extracellular matrix and increased in vivo sarcomere length (2011) J Physiol, 589, pp. 2625-2639. , PID: 21486759
Cosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.M., Gilja, O.H., EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 2: Clinical applications (2013) Ultraschall Med, 34, pp. 238-253. , PID: 23605169
Bortolotto, C., Lungarotti, L., Fiorina, I., Zacchino, M., Draghi, F., Calliada, F., Influence of subjects’ characteristics and technical variables on muscle stiffness measured by shear wave elastosonography (2017) J Ultrasound, 20 (2), pp. 139-146. , PID: 28593004
Minafra, P., Bortolotto, C., Rampinini, E., Calliada, F., Monetti, G., Quantitative elastosonography of the myotendinous junction: normal behavior and correlation with a standard measurement system during functional tests (2017) J Ultrasound Med, 36 (1), pp. 141-147. , PID: 27925702
Brandenburg, J.E., Eby, S.F., Song, P., Kingsley-Berg, S., Bamlet, W., Sieck, G.C., Quantifying passive muscle stiffness in children with and without cerebral palsy using ultrasound shear wave elastography (2016) Dev Med Child Neurol, 58, pp. 1288-1294
Lee, S.S., Gaebler-Spira, D., Zhang, L.Q., Rymer, W.Z., Steele, K.M., Use of shear wave ultrasound elastography to quantify muscle properties in cerebral palsy (2016) Clin Biomech, 31, pp. 20-28
Use of ultrasound shear wave to measure muscle stiffness in children with cerebral palsy
Kim YH, Shin SW, Pellicano R, Fagoonee S, Choi IJ, Kim YI, Park B, Choi JM, Kim SG, Choi J, Park JY, Oh S, Yang HJ, Lim JH, Im JP, Kim JS, Jung HC, Ponzetto A, Figura N, Malfertheiner P, Choi IJ, Kook MC, Kim YI, Cho SJ, Lee JY, Kim CG, Park B, Nam BH, Bae SE, Choi KD, Choe J, Kim SO, Na HK, Choi JY, Ahn JY, Jung KW, Lee J, Kim DH, Chang HS, Song HJ, Lee GH, Jung HY, Seta T, Takahashi Y, Noguchi Y, Shikata S, Sakai T, Sakai K, Yamashita Y, Nakayama T, Leja M, Park JY, Murillo R, Liepniece-karele I, Isajevs S, Kikuste I, Rudzite D, Krike P, Parshutin S, Polaka I, Kirsners A, Santare D, Folkmanis V, Daugule I, Plummer M, Herrero R, Tsukamoto T, Nakagawa M, Kiriyama Y, Toyoda T, Cao X, Corral JE, Mera R, Dye CW, Morgan DR, Lee YC, Lin JT, Garcia Martin R, Matia Cubillo A, Lee SH, Park JM, Han YM, Ko WJ, Hahm KB, Leontiadis GI, Ford AC, Ichinose M, Sugano K, Jeong M, Park JM, Han YM, Park KY, Lee DH, Yoo JH, Cho JY, Hahm KB, Bang CS, Baik GH, Shin IS, Kim JB, Suk KT, Yoon JH, Kim YS, Kim DJ * Helicobacter pylori Eradication for Prevention of Metachronous Recurrence after Endoscopic Resection of Early Gastric Cancer(297 views) N Engl J Med (ISSN: 0028-4793, 0028-4793linking, 1533-4406electronic), 2015 Jun; 30642104201566393291: 749-756. Impact Factor:59.558 ViewExport to BibTeXExport to EndNote