Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT(603 views)(PDF public259 views) Varrone A, Sjoholm N, Eriksson L, Gulyas B, Halldin C, Farde L
Keywords: Modelling, Partial Volume Effect, Resolution, Small Brain Nuclei, Dopamine 2 Receptor, Dopamine Transporter, Fe Pe2i F 18, Mnpa C 11, Raclopride C 11, Radioligand, Unclassified Drug, Algorithm, Animal Experiment, Area Under The Curve, Article, Computer Assisted Tomography, Controlled Study, Drug Binding, Drug Uptake, Female, Gray Matter, High Resolution Research Tomograph, Human, Human Experiment, Image Enhancement, Image Quality, Image Reconstruction, Imaging System, Intermethod Comparison, Mathematical Computing, Molecular Imaging, Monkey, Nonhuman, Normal Human, Poisson 3d Ordered Subset Expectation Maximization Algorithm, Poisson 3d Ordered Subset Expectation Maximization Point Spread Function Algorithm, Positron Emission Tomography, White Matter, Apomorphine, Carbon Radioisotopes, Dopamine Agonists, Dopamine Antagonists, Fluorine Radioisotopes, Image Processing, Computer-Assisted, Macaca Fascicularis, Statistical, Phantoms, Positron-Emission Tomography, Radiopharmaceuticals,
Affiliations: *** IBB - CNR ***
Department of Clinical Neuroscience, Psychiatry Section and Stockholm Brain Institute, Karolinska Hospital, Stockholm 17176, Sweden
Siemens Molecular Imaging, Knoxville, TN, United States
Department of Physics, University of Stockholm, Stockholm, Sweden
References: De Jong, H.W.A.M., Van Velden, F.H.P., Kloet, R.W., Buijs, F.L., Boellaard, R., Lammertsma, A.A., Performance evaluation of the ECAT HRRT: An LSO-LYSO double layer high resolution, high sensitivity scanner (2007) Physics in Medicine and Biology, 52 (5), pp. 1505-1526. , DOI 10.1088/0031-9155/52/5/019, PII S0031915507331710, 01
Heiss, W.D., Habedank, B., Klein, J.C., Herholz, K., Wienhard, K., Lenox, M., Metabolic rates in small brain nuclei determined by high-resolution PET (2004) J Nucl Med, 45, pp. 1811-1815. , 15534048
Horti, A.G., Fan, H., Kuwabara, H., Hilton, J., Ravert, H.T., Holt, D.P., 11C-JHU75528: A radiotracer for PET imaging of CB1 cannabinoid receptors (2006) J Nucl Med, 47, pp. 1689-1696. , 17015906 1:CAS:528:DC%2BD28XhtFKjtrbK
Leroy, C., Comtat, C., Trebossen, R., Syrota, A., Martinot, J.-L., Ribeiro, M.-J., Assessment of 11C-PE2I binding to the neuronal dopamine transporter in humans with the high-spatial-resolution PET scanner HRRT (2007) Journal of Nuclear Medicine, 48 (4), pp. 538-546. , http://jnm.snmjournals.org/cgi/reprint/48/4/538, DOI 10.2967/jnumed.106.037283
Hirvonen, J., Johansson, J., Teras, M., Oikonen, V., Lumme, V., Virsu, P., Roivainen, A., Hietala, J., Measurement of striatal and extrastriatal dopamine transporter binding with high-resolution PET and [11C]PE2I: Quantitative modeling and test-retest reproducibility (2008) Journal of Cerebral Blood Flow and Metabolism, 28 (5), pp. 1059-1069. , DOI 10.1038/sj.jcbfm.9600607, PII 9600607
Panin, V.Y., Kehren, F., Michel, C., Casey, M., Fully 3-D PET reconstruction with system matrix derived from point source measurements (2006) IEEE Transactions on Medical Imaging, 25 (7), pp. 907-921. , DOI 10.1109/TMI.2006.876171, 1644806
Sureau, F.C., Reader, A.J., Comtat, C., Leroy, C., Ribeiro, M.-J., Buvat, I., Trebossen, R., Impact of image-space resolution modeling for studies with the high-resolution research tomograph (2008) Journal of Nuclear Medicine, 49 (6), pp. 1000-1008. , http://jnm.snmjournals.org/cgi/reprint/49/6/1000, DOI 10.2967/jnumed.107.045351
Quarantelli, M., Berkouk, K., Prinster, A., Landeau, B., Svarer, C., Balkay, L., Integrated software for the analysis of brain PET/SPECT studies with partial-volume-effect correction (2004) J Nucl Med, 45, pp. 192-201. , 14960635
Rousset, O.G., Ma, Y., Evans, A.C., Correction for partial volume effects in PET: Principle and validation (1998) J Nucl Med, 39, pp. 904-911. , 9591599 1:STN:280:DyaK1c3lt1aksQ%3D%3D
Rousset, O.G., Deep, P., Kuwabara, H., Evans, A.C., Gjedde, A.H., Cumming, P., Effect of partial volume correction on estimates of the influx and cerebral metabolism of 6-[(18) F]fluoro-L-dopa studied with PET in normal control and Parkinson's disease subjects (2000) Synapse, 37, pp. 81-89. , 10.1002/1098-2396(200008) 37:2<81::AID-SYN1>
3.0.CO
Müller-Gärtner, H.W., Links, J.M., Prince, J.L., Bryan, R.N., McVeigh, E., Leal, J.P., Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects (1992) J Cereb Blood Flow Metab, 12, pp. 571-583. , 1618936
Hong, I.K., Chung, S.T., Kim, H.K., Kim, Y.B., Son, Y.D., Cho, Z.H., Ultra fast symmetry and SIMD-based projection-backprojection (SSP) algorithm for 3-D PET image reconstruction (2007) IEEE Transactions on Medical Imaging, 26 (6), pp. 789-803. , DOI 10.1109/TMI.2007.892644
Comtat, C., Sureau, F.C., Sibomana, M., Hong, I.K., Sjöholm, N., Trébossen, R., Image based resolution modeling for the HRRT OSEM reconstructions software (2008) IEEE Nuclear Science Symposium Conference Record, , Paper presented at Dresden, Germany
Joseph, P.M., An improved algorithm for reprojecting rays through pixel images (1982) IEEE Trans Med Imaging, 1, pp. 192-196. , 10.1109/TMI.1982.4307572 18238275 10.1109/TMI.1982.4307572 1:STN:280:DC%2BD1c%2FotFejsA%3D%3D
Daube-Witherspoon, M.E., Karp, J.S., Casey, M.E., Difilippo, F.P., Hines, H., Muehllehner, G., PET performance measurements using the NEMA NU 2-2001 standard (2002) J Nucl Med, 43, pp. 1398-1409. , 12368380
Reilhac, A., Tomei, S., Buvat, I., Michel, C., Keheren, F., Costes, N., Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies (2008) NeuroImage, 39 (1), pp. 359-368. , DOI 10.1016/j.neuroimage.2007.07.038, PII S1053811907006659
Alfano, B., Prinster, A., Quarantelli, M., Brunetti, A., Salvatore, M., STEPBRAIN: A stereolitographed phantom of the brain for nuclear medicine, computed tomography, and magnetic resonance applications (2003) RSNA, , Paper presented at
Odano, I., Halldin, C., Karlsson, P., Varrone, A., Airaksinen, A.J., Krasikova, R.N., [(18)F]Flumazenil binding to central benzodiazepine receptor studies by PET-quantitative analysis and comparisons with [(11)C]flumazenil (2009) Neuroimage, 45, pp. 891-902. , 19136064 10.1016/j.neuroimage.2008.12.005
Clark, J.D., Gebhart, G.F., Gonder, J.C., Keeling, M.E., Kohn, D.F., Special Report: The 1996 Guide for the Care and Use of Laboratory Animals (1997) ILAR J, 38, pp. 41-48. , 11528046
Varrone, A., Steiger, C., Schou, M., Takano, A., Finnema, S.J., Guilloteau, D., In vitro autoradiography and in vivo evaluation in cynomolgus monkey of [18F]FE-PE2I, a new dopamine transporter PET radioligand (2009) Synapse, , In press
Finnema, S.J., Seneca, N., Farde, L., Shchukin, E., Sovago, J., Gulyas, B., Wikstrom, H.V., Halldin, C., A preliminary PET evaluation of the new dopamine D2 receptor agonist [11C]MNPA in cynomolgus monkey (2005) Nuclear Medicine and Biology, 32 (4), pp. 353-360. , DOI 10.1016/j.nucmedbio.2005.01.007, PII S0969805105000430
Karlsson, P., Farde, L., Halldin, C., Swahn, C.-G., Sedvall, G., Foged, C., Hansen, K.T., Skrumsager, B., PET examination of [11C]NNC 687 and [11C]NNC 756 as new radioligands for the D1-dopamine receptor (1993) Psychopharmacology, 113 (2), pp. 149-156. , DOI 10.1007/BF02245691
Lammertsma, A.A., Hume, S.P., Simplified reference tissue model for PET receptor studies (1996) NeuroImage, 4 (3), pp. 153-158. , DOI 10.1006/nimg.1996.0066
Farde, L., Hall, H., Ehrin, E., Sedvall, G., Quantitative analysis of D2 dopamine receptor binding in the living human brain by PET (1986) Science, 231, pp. 258-261. , 10.1126/science.2867601 2867601 10.1126/science.2867601 1:CAS:528:DyaL28XmsFaktg%3D%3D
Bergstrom, M., Boethius, J., Eriksson, L., Head fixation device for reproducible position alignment in transmission CT and positron emission tomography (1981) Journal of Computer Assisted Tomography, 5 (1), pp. 136-141. , DOI 10.1097/00004728-198102000-00027
Roland, P.E., Graufelds, C.J., Wahlin, J., Ingelman, L., Andersson, M., Ledberg, A., Human brain atlas: For high-resolution functional and anatomical mapping (1994) Hum Brain Mapp, 1, pp. 173-184. , 10.1002/hbm.460010303 10.1002/hbm.460010303
Giovacchini, G., Toczek, M.T., Bonwetsch, R., Bagic, A., Lang, L., Fraser, C., 5-HT 1A receptors are reduced in temporal lobe epilepsy after partial-volume correction (2005) J Nucl Med, 46, pp. 1128-1135. , 16000281
Hasselbalch, S.G., Madsen, K., Svarer, C., Pinborg, L.H., Holm, S., Paulson, O.B., Reduced 5-HT2A receptor binding in patients with mild cognitive impairment (2008) Neurobiol Aging, 29, pp. 1830-1838. , 10.1016/j.neurobiolaging.2007.04.011 17544547 10.1016/j.neurobiolaging. 2007.04.011 1:CAS:528:DC%2BD1cXht1KnsL7K
De Jong, H. W. A. M., Van Velden, F. H. P., Kloet, R. W., Buijs, F. L., Boellaard, R., Lammertsma, A. A., Performance evaluation of the ECAT HRRT: An LSO-LYSO double layer high resolution, high sensitivity scanner (2007) Physics in Medicine and Biology, 52 (5), pp. 1505-1526. , DOI 10. 1088/0031-9155/52/5/019, PII S0031915507331710, 01
Heiss, W. D., Habedank, B., Klein, J. C., Herholz, K., Wienhard, K., Lenox, M., Metabolic rates in small brain nuclei determined by high-resolution PET (2004) J Nucl Med, 45, pp. 1811-1815. , 15534048
Horti, A. G., Fan, H., Kuwabara, H., Hilton, J., Ravert, H. T., Holt, D. P., 11C-JHU75528: A radiotracer for PET imaging of CB1 cannabinoid receptors (2006) J Nucl Med, 47, pp. 1689-1696. , 17015906 1: CAS: 528: DC%2BD28XhtFKjtrbK
Panin, V. Y., Kehren, F., Michel, C., Casey, M., Fully 3-D PET reconstruction with system matrix derived from point source measurements (2006) IEEE Transactions on Medical Imaging, 25 (7), pp. 907-921. , DOI 10. 1109/TMI. 2006. 876171, 1644806
Sureau, F. C., Reader, A. J., Comtat, C., Leroy, C., Ribeiro, M. -J., Buvat, I., Trebossen, R., Impact of image-space resolution modeling for studies with the high-resolution research tomograph (2008) Journal of Nuclear Medicine, 49 (6), pp. 1000-1008. , http: //jnm. snmjournals. org/cgi/reprint/49/6/1000, DOI 10. 2967/jnumed. 107. 045351
Rousset, O. G., Ma, Y., Evans, A. C., Correction for partial volume effects in PET: Principle and validation (1998) J Nucl Med, 39, pp. 904-911. , 9591599 1: STN: 280: DyaK1c3lt1aksQ%3D%3D
Rousset, O. G., Deep, P., Kuwabara, H., Evans, A. C., Gjedde, A. H., Cumming, P., Effect of partial volume correction on estimates of the influx and cerebral metabolism of 6- [(18) F] fluoro-L-dopa studied with PET in normal control and Parkinson's disease subjects (2000) Synapse, 37, pp. 81-89. , 10. 1002/1098-2396 (200008) 37: 2<81:: AID-SYN1>
3. 0. CO
M ller-G rtner, H. W., Links, J. M., Prince, J. L., Bryan, R. N., McVeigh, E., Leal, J. P., Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects (1992) J Cereb Blood Flow Metab, 12, pp. 571-583. , 1618936
Hong, I. K., Chung, S. T., Kim, H. K., Kim, Y. B., Son, Y. D., Cho, Z. H., Ultra fast symmetry and SIMD-based projection-backprojection (SSP) algorithm for 3-D PET image reconstruction (2007) IEEE Transactions on Medical Imaging, 26 (6), pp. 789-803. , DOI 10. 1109/TMI. 2007. 892644
Joseph, P. M., An improved algorithm for reprojecting rays through pixel images (1982) IEEE Trans Med Imaging, 1, pp. 192-196. , 10. 1109/TMI. 1982. 4307572 18238275 10. 1109/TMI. 1982. 4307572 1: STN: 280: DC%2BD1c%2FotFejsA%3D%3D
Clark, J. D., Gebhart, G. F., Gonder, J. C., Keeling, M. E., Kohn, D. F., Special Report: The 1996 Guide for the Care and Use of Laboratory Animals (1997) ILAR J, 38, pp. 41-48. , 11528046
Finnema, S. J., Seneca, N., Farde, L., Shchukin, E., Sovago, J., Gulyas, B., Wikstrom, H. V., Halldin, C., A preliminary PET evaluation of the new dopamine D2 receptor agonist [11C] MNPA in cynomolgus monkey (2005) Nuclear Medicine and Biology, 32 (4), pp. 353-360. , DOI 10. 1016/j. nucmedbio. 2005. 01. 007, PII S0969805105000430
Lammertsma, A. A., Hume, S. P., Simplified reference tissue model for PET receptor studies (1996) NeuroImage, 4 (3), pp. 153-158. , DOI 10. 1006/nimg. 1996. 0066
Roland, P. E., Graufelds, C. J., Wahlin, J., Ingelman, L., Andersson, M., Ledberg, A., Human brain atlas: For high-resolution functional and anatomical mapping (1994) Hum Brain Mapp, 1, pp. 173-184. , 10. 1002/hbm. 460010303 10. 1002/hbm. 460010303
Hasselbalch, S. G., Madsen, K., Svarer, C., Pinborg, L. H., Holm, S., Paulson, O. B., Reduced 5-HT2A receptor binding in patients with mild cognitive impairment (2008) Neurobiol Aging, 29, pp. 1830-1838. , 10. 1016/j. neurobiolaging. 2007. 04. 011 17544547 10. 1016/j. neurobiolaging. 2007. 04. 011 1: CAS: 528: DC%2BD1cXht1KnsL7K
Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT
Antonini A, Vitale C, Barone P, Cilia R, Righini A, Bonuccelli U, Abbruzzese G, Ramat S, Petrone A, Quatrale R, Marconi R, Ceravolo R, Stefani A, Lopiano L, Zappia M, Capus L, Morgante L, Tamma F, Tinazzi M, Colosimo C, Guerra UP, Valzania F, Fagioli G, Distefano A, Bagnato A, Feggi L, Anna S, Maria Teresa Rosaria De Cr, Nobili F, Mazzuca N, Baldari S, Eleopra R, Bestetti A, Benti R, Varrone A, Volterrani D, Massa R, Stocchi F, Schillaci O, Dore F, Zibetti M, Castellano G, Battista SG, Giorgetti G * The relationship between cerebral vascular disease and parkinsonism: The VADO study(496 views) Parkinsonism Relat D (ISSN: 1353-8020, 1873-5126, 1873-5126electronic), 2012; 18(6): 775-780. Impact Factor:3.274 ViewExport to BibTeXExport to EndNote
Cusanno F, Cisbani E, Colilli S, Fratoni R, Garibaldi F, Giuliani F, Gricia M, Lucentini M, Magliozzi ML, Santarivenere F, Torrioli S, Cinti MN, Pani R, Pellegrini R, Simonetti G, Schillaci O, Del Vecchio S, Salvatore M, Majewski S, De Vincentis G, Scopinaro F * Results of clinical trials with SPEM(278 views) Nucl Instrum Methods Phys Res Sect A, 2007 Feb 1; 497(1): 46-50. Impact Factor:3.221 ViewExport to BibTeXExport to EndNote
Aloj L, Aurilio M, Rinaldi V, D'Ambrosio L, Tesauro D, Peitl PK, Maina T, Mansi R, Von Guggenberg E, Joosten L, Sosabowski JK, Breeman WA, De Blois E, Koelewijn S, Melis M, Waser B, Beetschen K, Reubi JC, De Jong M * The EEE project(449 views) Proc Int Cosm Ray Conf Icrc Universidad Nacional Autonoma De Mexico, 2007; 5(HEPART2): 977-980. Impact Factor:0 ViewExport to BibTeXExport to EndNote