Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: comparison of two different approaches
Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: comparison of two different approaches(1958 views) Storto G, Soricelli A, Pellegrino T, Petretta M, Cuocolo A
IRCCS, CROB, Rionero in Vulture, Italy.
SDN Foundation, Institute of Diagnostic and Nuclear Development, Naples, Italy
Department of Biomorphological and Functional Sciences, Institute of Biostructures and Bioimages, University Federico II, Naples, Italy
Department of Clinical Medicine, Cardiovascular and Immunological Sciences, University Federico II, Naples, Italy
References: Nicolai, E., Cuocolo, A., Pace, L., Nappi, A., Sullo, P., Cardei, S., Adenosine coronary vasodilatation quantitative technetium 99m methoxy isobutyl isonitrile myocardial tomography in the identification and localization of coronary artery disease (1996) J Nucl Cardiol, 3, pp. 9-17. , 10.1016/S1071-3581(96) 90019-7 10.1016/S1071-3581(96)90019-7 1:STN:280:DyaK28zpt1Cgtw%3D%3D 879922
Miller, D.D., Younis, L.T., Chaitman, B.R., Stratmann, H., Diagnostic accuracy of dipyridamole technetium 99m-labelled sestamibi myocardial tomography for detection of coronary artery disease (1997) J Nucl Cardiol, 4, pp. 18-24. , 10.1016/S1071-3581(97) 90045-3 10.1016/S1071-3581(97)90045-3 1:STN:280:DyaK2s3gs1Sltw%3D%3D 9138835
Heller, G.V., Herman, S.D., Travin, M.I., Baron, J.I., Santos-Ocampo, C., McClellan, J.R., Independent prognostic value of intravenous dipyridamole with technetium-99m sestamibi tomographic imaging in predicting cardiac events and cardiac-related hospital admissions (1995) J Am Coll Cardiol, 26, pp. 1202-1208. , 10.1016/0735-1097(95) 00329-0 10.1016/0735-1097(95)00329-0 1:STN:280:DyaK28%2Fjtlyktg%3D%3D 7594033
Stratmann, H.G., Tamesis, B.R., Younis, L.T., Wittry, M.D., Amato, M., Miller, D.D., Prognostic value of predischarge dipyridamole technetium 99m sestamibi myocardial tomography in medically treated patients with unstable angina (1995) Am Heart J, 130, pp. 734-740. , 10.1016/0002-8703(95) 90071-3 10.1016/0002-8703(95)90071-3 1:STN:280:DyaK28%2FitFajug%3D%3D 7572580
Germano, G., Technical aspects of myocardial SPECT imaging (2001) J Nucl Med, 42, pp. 1499-1507. , 1:STN:280:DC%2BD3MrjvFSluw%3D%3D 11585864
Klocke, F.J., Measurements of coronary flow reserve: Defining pathophysiology versus making decisions about patient care (1987) Circulation, 76, pp. 1183-1189. , 1:STN:280:DyaL1c%2Fltlagtw%3D%3D 2960470
Hoffman, J.I., A critical view of coronary reserve (1987) Circulation, 75, pp. 6-I11. , 1:STN:280:DyaL2s%2FnvVyjsw%3D%3D 2947752
Gould, K.L., Lipscomb, K., Hamilton, G.W., Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve (1974) Am J Cardiol, 33, pp. 87-94. , 10.1016/0002-9149(74) 90743-7 10.1016/0002-9149(74)90743-7 1:STN:280:DyaE2c%2FkslCjtg%3D%3D 4808557
Baller, D., Notohamiprodjo, G., Gleichmann, U., Holzinger, J., Weise, R., Lehmann, J., Improvement in coronary flow reserve determined by positron emission tomography after 6 months of cholesterol-lowering therapy in patients with early stages of coronary atherosclerosis (1999) Circulation, 99, pp. 2871-2875. , 1:STN:280:DyaK1M3ovFKqsg%3D%3D 10359730
Doucette, J.W., Corl, P.D., Payne, H.M., Flynn, A.E., Goto, M., Nassi, M., Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity (1992) Circulation, 85, pp. 1899-1911. , 1:STN:280:DyaK383ktVOktQ%3D%3D 1572046
Aude, Y.W., Garza, L., How to prevent unnecessary coronary interventions: Identifying lesions responsible for ischemia in the cath lab (2003) Current Opinion in Cardiology, 18 (5), pp. 394-399. , DOI 10.1097/00001573-200309000-00012
Bergmann, S.R., Fox, K.A., Rand, A.L., McElvany, K.D., Welch, M.J., Markham, J., Quantification of regional myocardial blood flow in vivo with H215O (1984) Circulation, 70, pp. 724-733. , 1:STN:280:DyaL2M%2Fgt1agtw%3D%3D 6332687
Araujo, L.I., Lammertsma, A.A., Rhodes, C.G., McFalls, E.O., Iida, H., Rechavia, E., Noninvasive quantification of regional myocardial blood flow in coronary artery disease with oxygen-15-labeled carbon dioxide inhalation and positron emission tomography (1991) Circulation, 83, pp. 875-885. , 1:STN:280:DyaK3M7lt1yqtw%3D%3D 1900224
Iida, H., Kanno, I., Takahashi, A., Miura, S., Murakami, M., Takahashi, K., Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume effect (1988) Circulation, 78, pp. 104-115. , 1:STN:280:DyaL1c3ltlOmug%3D%3D 3260151
Storto, G., Cirillo, P., Eufrasia Vicario, M.L., Pellegrino, T., Sorrentino, A.R., Petretta, M., Galasso, G., Cuocolo, A., Estimation of coronary flow reserve by Tc-99m sestamibi imaging in patients with coronary artery disease: Comparison with the results of intracoronary Doppler technique (2004) Journal of Nuclear Cardiology, 11 (6), pp. 682-688. , DOI 10.1016/j.nuclcard.2004.08.007, PII S107135810400399X
Sugihara, H., Yonekura, Y., Kataoka, K., Fukai, D., Kitamura, N., Taniguchi, Y., Estimation of coronary flow reserve with the use of dynamic planar and SPECT images of Tc-99m tetrofosmin (2001) Journal of Nuclear Cardiology, 8 (5), pp. 575-579. , DOI 10.1067/mnc.2001.115934
Taki, J., Fujino, S., Nakajima, K., Matsunari, I., Okazaki, H., Saga, T., (99m)Tc-sestamibi retention characteristics during pharmacologic hyperemia in human myocardium: Comparison with coronary flow reserve measured by Doppler flowire (2001) J Nucl Med, 42, pp. 1457-1463. , 1:STN:280:DC%2BD3MrjvFSlsA%3D%3D 11585857
Ito, Y., Katoh, C., Noriyasu, K., Kuge, Y., Furuyama, H., Morita, K., Estimation of myocardial blood flow and myocardial flow reserve by 99mTc-sestamibi imaging: Comparison with the results of [15O]H2O PET (2003) Eur J Nucl Med Mol Imaging, 30, pp. 281-287. , 1:CAS:528:DC%2BD3sXms1Cmsg%3D%3D 12552347
Brunken, R.C., Challenges for measurement of myocardial perfusion and perfusion reserve by SPECT imaging (2007) Journal of Nuclear Cardiology, 14 (2), pp. 145-149. , DOI 10.1016/j.nuclcard.2007.01.034, PII S1071358107001067
Ragosta, M., The clinical assessment of coronary flow reserve in patients with coronary artery disease (2004) Journal of Nuclear Cardiology, 11 (6), pp. 651-655. , DOI 10.1016/j.nuclcard.2004.09.010, PII S1071358104004453
Gullberg, G.T., Di Bella, E.V.R., Sinusas, A.J., Estimation of coronary flow reserve: Can SPECT compete with other modalities? (2001) Journal of Nuclear Cardiology, 8 (5), pp. 620-625. , DOI 10.1067/mnc.2001.118121
Vicario, M.L., Cirillo, L., Storto, G., Pellegrino, T., Ragone, N., Fontanella, L., Influence of risk factors on coronary flow reserve in patients with 1-vessel coronary artery disease (2005) J Nucl Med, 46, pp. 1438-1443. , 16157525
Pellegrino, T., Storto, G., Filardi, P.P., Sorrentino, A.R., Silvestro, A., Petretta, M., Brevetti, G., Cuocolo, A., Relationship between brachial artery flow-mediated dilation and coronary flow reserve in patients with peripheral artery disease (2005) Journal of Nuclear Medicine, 46 (12), pp. 1997-2002
Perrone-Filardi, P., Cuocolo, A., Brevetti, G., Silvestro, A., Storto, G., Dellegrottaglie, S., Corrado, L., Chiariello, M., Relation of brachial artery flow-mediated vasodilation to significant coronary artery disease in patients with peripheral arterial disease (2005) American Journal of Cardiology, 96 (9), pp. 1337-1341. , DOI 10.1016/j.amjcard.2005.06.084, PII S000291490501283X
Storto, G., Sorrentino, A.R., Pellegrino, T., Liuzzi, R., Petretta, M., Cuocolo, A., Assessment of coronary flow reserve by sestamibi imaging in patients with typical chest pain and normal coronary arteries (2007) European Journal of Nuclear Medicine and Molecular Imaging, 34 (8), pp. 1156-1161. , DOI 10.1007/s00259-006-0333-x
Palmieri, V., Storto, G., Arezzi, E., Pellegrino, T., Mancini, M., Di Minno, G., Ferrara, A.L., Celentano, A., Relations of left ventricular mass and systolic function to endothelial function and coronary flow reserve in healthy, new discovered hypertensive subjects (2005) Journal of Human Hypertension, 19 (12), pp. 941-950. , DOI 10.1038/sj.jhh.1001921, PII 1001921
Petretta, M., Soricelli, A., Storto, G., Cuocolo, A., Assessment of coronary flow reserve using single photon emission computed tomography with technetium 99m-labeled tracers (2008) Journal of Nuclear Cardiology, 15 (3), pp. 456-465. , DOI 10.1016/j.nuclcard.2008.03.008, PII S1071358108001293
Lette, J., Tatum, J.L., Fraser, S., Miller, D.D., Waters, D.D., Heller, G., Safety of dipyridamole testing in 73,806 patients: The Multicenter Dipyridamole Safety Study (1995) J Nucl Cardiol, 2, pp. 3-17. , 10.1016/S1071-3581(05) 80003-0 10.1016/S1071-3581(05)80003-0 1:STN:280:DyaK1c%2Fot1ehtQ%3D%3D 9420757
Bland, J.M., Altman, D.G., Statistical methods for assessing agreement between two methods of clinical measurement (1986) Lancet, 1, pp. 307-310. , 1:STN:280:DyaL287hslWqsQ%3D%3D 2868172
Marcus, M.L., Wilson, R.F., White, C.W., Methods of measurement of myocardial blood flow in patients: A critical review (1987) Circulation, 76, pp. 245-253. , 1:STN:280:DyaL2s3nsVSjsQ%3D%3D 2955953
Hoffman, J.I.E., Problems of coronary flow reserve (2000) Annals of Biomedical Engineering, 28 (8), pp. 884-896. , DOI 10.1114/1.1308503
De Bruyne, B., Baudhuin, T., Melin, J.A., Pijls, N.H., Sys, S.U., Bol, A., Coronary flow reserve calculated from pressure measurements in humans. Validation with positron emission tomography (1994) Circulation, 89, pp. 1013-1022. , 8124786
Saraste, M., Koskenvuo, J.W., Knuuti, J., Toikka, J.O., Laine, H., Niemi, P., Sakuma, H., Hartiala, J.J., Coronary flow reserve: Measurement with transthoracic Doppler echocardiography is reproducible and comparable with positron emission tomography (2001) Clinical Physiology, 21 (1), pp. 114-122. , DOI 10.1046/j.1365-2281.2001.00296.x
Germain, P., Roul, G., Baruthio, J., Jahn, C., Coulbois, P.M., Dumitresco, B., Dietemann, J.L., Constantinesco, A., Myocardial flow reserve parametric map, assessed by first-pass MRI compartmental analysis at the chronic stage of infarction (2001) Journal of Magnetic Resonance Imaging, 13 (3), pp. 352-360. , DOI 10.1002/jmri.1050
Koskenvuo, J.W., Sakuma, H., Niemi, P., Toikka, J.O., Knuuti, J., Laine, H., Komu, M., Hartiala, J.J., Global myocardial blood flow and global flow reserve measurements by MRI and PET are comparable (2001) Journal of Magnetic Resonance Imaging, 13 (3), pp. 361-366. , DOI 10.1002/jmri.1051
Bergmann, S.R., Herrero, P., Markham, J., Weinheimer, C.J., Walsh, M.N., Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography (1989) Journal of the American College of Cardiology, 14 (3), pp. 639-652
Joye, J.D., Schulman, D.S., Clinical application of coronary flow reserve using an intracoronary Doppler guide wire (1997) Cardiol Clin, 15, pp. 101-129. , 10.1016/S0733-8651(05) 70321-0 10.1016/S0733-8651(05)70321-0 1:STN:280:DyaK2s3ktVejuw%3D%3D 9085755
Labovitz, A.J., Anthonis, D.M., Cravens, T.L., Kern, M.J., Validation of volumetric flow measurements by means of a Doppler-tipped coronary angioplasty guide wire (1993) Am Heart J, 126, pp. 1456-1461. , 10.1016/0002-8703(93) 90545-K 10.1016/0002-8703(93)90545-K 1:STN:280:DyaK2c%2FntVKjug%3D%3D 8249803
Kern, M.J., Deligonul, U., Tatineni, S., Serota, H., Aguirre, F., Hilton, T.C., Intravenous adenosine: Continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease (1991) J Am Coll Cardiol, 18, pp. 718-729. , 1:STN:280:DyaK3Mzjt1ehsw%3D%3D 1869735
Rossen, J.D., Quillen, J.E., Lopez, A.G., Stenberg, R.G., Talman, C.L., Winniford, M.D., Comparison of coronary vasodilatation with intravenous dipyridamole and adenosine (1991) J Am Coll Cardiol, 18, pp. 485-491. , 1:STN:280:DyaK3MzhtV2lug%3D%3D 1856416
Ogilby, J.D., Iskandrian, A.S., Untereker, W.J., Heo, J., Nguyen, T.N., Mercuro, J., Effect of intravenous adenosine infusion on myocardial perfusion and function. Hemodynamic/angiographic and scintigraphic study (1992) Circulation, 86, pp. 887-895. , 1:STN:280:DyaK38zos1Kruw%3D%3D 1516201
Masuda, D., Nohara, R., Tamaki, N., Hosokawa, R., Inada, H., Hikai, T., Evaluation of coronary blood flow reserve by 13 N-NH3 positron emission computed tomography (PET) with dipyridamole in the treatment of hypertension with the ACE inhibitor (Cilazapril) (2000) Ann Nucl Med, 14, pp. 353-360. , 10.1007/BF02988695 10.1007/BF02988695 1:CAS:528:DC%2BD3MXkvFWmsw%3D%3D 11108164
Yokoyama, I., Ohtake, T., Momomura, S., Nishikawa, J., Sasaki, Y., Omata, M., Reduced coronary flow reserve in hypercholesterolemic patients without overt coronary stenosis (1996) Circulation, 94, pp. 3232-3238. , 1:STN:280:DyaK2s7ktlWhsQ%3D%3D 8989134
Lortie, M., Beanlands, R.S.B., Yoshinaga, K., Klein, R., DaSilva, J.N., DeKemp, R.A., Quantification of myocardial blood flow with 82Rb dynamic PET imaging (2007) European Journal of Nuclear Medicine and Molecular Imaging, 34 (11), pp. 1765-1774. , DOI 10.1007/s00259-007-0478-2
Lautamäki, R., George, R.T., Kitagawa, K., Higuchi, T., Merrill, J., Voicu, C., Rubidium-82 PET-CT for quantitative assessment of myocardial blood flow: Validation in a canine model of coronary artery stenosis (2009) Eur J Nucl Med Mol Imaging, 36, pp. 576-586. , 10.1007/s00259-008-0972-1 10.1007/s00259-008-0972-1 18985343
Castell-Conesa, J., Candell-Riera, J., Estimation of coronary flow reserve by SPECT: Myth or reality? (2007) European Journal of Nuclear Medicine and Molecular Imaging, 34 (8), pp. 1152-1155. , DOI 10.1007/s00259-007-0415-4
Gambhir, S.S., Schwaiger, M., Huang, S.C., Krivokapich, J., Schelbert, H.R., Nienaber, C.A., Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose (1989) J Nucl Med, 30, pp. 359-366. , 1:CAS:528:DyaK3cXmt1OhtL4%3D 2786939
Santana, C.A., Folks, R.D., Garcia, E.V., Verdes, L., Sanyal, R., Hainer, J., Di Carli, M.F., Esteves, F.P., Quantitative 82Rb PET/CT: Development and validation of myocardial perfusion database (2007) Journal of Nuclear Medicine, 48 (7), pp. 1122-1128. , DOI 10.2967/jnumed.107.039750
Katoh, C., Morita, K., Shiga, T., Kubo, N., Nakada, K., Tamaki, N., Improvement of algorithm for quantification of regional myocardial blood flow using 15O-water with PET (2004) J Nucl Med, 45, pp. 1908-1916. , 15534062
Choi, Y., Hawkins, R.A., Huang, S.C., Gambhir, S.S., Brunken, R.C., Phelps, M.E., Parametric images of myocardial metabolic rate of glucose generated from dynamic cardiac PET and 2-[18F]fluoro-2-deoxy-d-glucose studies (1991) J Nucl Med, 32, pp. 733-738. , 1:STN:280:DyaK3M7ptlyitA%3D%3D 2013815
O'Rourke, M.F., Yaginuma, T., Avolio, A.P., Physiological and pathophysiological implications of ventricular/vascular coupling (1984) Ann Biomed Eng, 12, pp. 119-134. , 10.1007/BF02584226 10.1007/BF02584226 6439084
Nakamura, M., Wada, S., Yamaguchi, T., Computational analysis of blood flow in an integrated model of the left ventricle and the aorta (2006) Journal of Biomechanical Engineering, 128 (6), pp. 837-843. , DOI 10.1115/1.2400864
Perlini, S., Soldà, P.L., Piepoli, M., Calciati, A., Paro, M., Marchetti, G., Time course of pressure and flow in ascending aorta during ejection (1991) Int J Cardiol, 30, pp. 169-179. , 10.1016/0167-5273(91) 90092-4 10.1016/0167-5273(91)90092-4 1:STN:280:DyaK3M7osV2hsw%3D%3D 1707037
Long, Q., Merrifield, R., Xu, X.Y., Kilner, P., Firmin, D.N., Subject-specific computational simulation of left ventricular flow based on magnetic resonance imaging (2008) Proc Inst Mech Eng [H], 222, pp. 475-485. , 10.1243/09544119JEIM310 1:STN:280:DC%2BD1cvislWhuw%3D%3D
McGinn, A.L., White, C.W., Wilson, R.F., Interstudy variability of coronary flow reserve. Influence of heart rate, arterial pressure, and ventricular preload (1990) Circulation, 81, pp. 1319-1330. , 1:STN:280:DyaK3c3gtVWhsA%3D%3D 2317912
Scherhag, A.W., Pfleger, S., De Mey, C., Schreckenberger, A.B., Staedt, U., Heene, D.L., Continuous measurement of hemodynamic alterations during pharmacologic cardiovascular stress using automated impedance cardiography (1997) J Clin Pharmacol, 37 (SUPPL), pp. 21S-28S. , 10.1177/009127009703700118 10.1177/009127009703700118 1:CAS:528:DyaK2sXhvFyiu7c%3D 9048281
Varga, A., Garcia, M.A.R., Picano, E., Safety of Stress Echocardiography (from the International Stress Echo Complication Registry) (2006) American Journal of Cardiology, 98 (4), pp. 541-543. , DOI 10.1016/j.amjcard.2006.02.064, PII S0002914906008319
Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: comparison of two different approaches
PURPOSE: Attempts to estimate coronary flow reserve (CFR) with single photon emission computed tomography (SPECT) tracers have been recently made. We compared two different methods for the estimation of CFR by SPECT imaging.; METHODS: Fourteen patients with coronary artery disease underwent dipyridamole 99mTc-sestamibi SPECT and intracoronary Doppler within 5 days. Myocardial blood flow (MBF) was estimated by measurement of first transit counts in the right pulmonary artery (PA) and left ventricular (LV) chamber, and myocardial counts from SPECT images. Estimated CFR was expressed as the ratio of stress MBF to rest MBF.; RESULTS: Rest and stress MBF obtained using first transit counts from PA were higher compared to that from LV chamber (rest: 1.05 ± 0.38 vs 0.87 ± 0.34 counts/pixel per s, respectively, p < 0.01 and stress: 1.34 ± 0.45 vs 0.91 ± 0.20 counts/pixel per s, respectively, p < 0.05). In the study vessels, CFR by Doppler was 1.39 ± 0.42, and SPECT CFR obtained using first transit counts from PA and LV chamber were 1.36 ± 0.43 and 1.16 ± 0.39, respectively (p across categories NS). A significant relationship between SPECT CFR obtained using first transit counts from PA and CFR by Doppler was found (r = 0.85, p < 0.001). No relationship between SPECT CFR obtained using first transit counts from LV chamber and CFR by intracoronary Doppler was OBSERVED (R = 0.43, P = NS).; CONCLUSION: SPECT-estimated CFR obtained using first transit counts from right PA is more accurate and correlates better with the results of intracoronary Doppler than estimated CFR obtained using arterial input function from LV chamber.
Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: comparison of two different approaches
Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: comparison of two different approaches
Hesse B, Tagil K, Cuocolo A, Anagnostopoulos C, Bardies M, Bax J, Bengel F, Busemann Sokole E, Davies G, Dondi M, Edenbrandt L, Franken P, Kjaer A, Knuuti J, Lassmann M, Ljungberg M, Marcassa C, Marie PY, Mckiddie F, O'connor M, Prvuolovich E, Underwood R * 3. 0 T perfusion MR imaging(694 views) Rivista Di Neuroradiologia (ISSN: 1120-9976), 2004; 17(6): 807-812. Impact Factor:0.023 ViewExport to BibTeXExport to EndNote