3. 0 T perfusion MR imaging(726 views) Hesse B, Tagil K, Cuocolo A, Anagnostopoulos C, Bardies M, Bax J, Bengel F, Busemann Sokole E, Davies G, Dondi M, Edenbrandt L, Franken P, Kjaer A, Knuuti J, Lassmann M, Ljungberg M, Marcassa C, Marie PY, Mckiddie F, O'connor M, Prvuolovich E, Underwood R
Rivista Di Neuroradiologia (ISSN: 1120-9976), 2004; 17(6): 807-812.
Neuroradiologia, Dipartimento di Scienze Radiologiche, Ist. Sci. Casa Sollievo Sofferenza, San Giovanni Rotondo, Foggia, Italy
Radiologia, Università di Novara, Italy
Neurologia, Università di Napoli, Italy
Neuroradiologia, Università di Ancona, Italy
Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark
Department of Biomorphological and Functional Sciences, University Federico II, Naples, Italy
Imperial College School of Medicine (NHLI), London, United Kingdom
INSERM U601, Nantes, France
Department of Cardiology, Leiden University Medical Center, Leiden, Netherlands
Nuklearmedizinische Klinik der TU, Munich, Germany
Department of Nuclear Medicine, Academic Medical Center, Amsterdam, Netherlands
Department of Medical Physics, Hull and East Yorkshire Hospitals NHS Trust, Hull, United Kingdom
Nuclear Medicine Section, Division of Human Health, International Atomic Energy Agency, Vienna, Austria
Nuclear Medicine, AZ VUB, Brussels, Belgium
Turku PET Centre, Turku University Central Hospital, Turku, Finland
Klinik f r Nuklearmedizin, Universit t W rzburg, W rzburg, Germany
Fondazione Maugeri, IRCCS, Verona, Italy
Service de M decine Nucl aire, H pital de Brabois, Vandoeuvre, France
Nuclear Medicine Department, Aberdeen Royal Infirmary, Foresterhill, United Kingdom
Section of Nuclear Medicine, Mayo Clinic, Rochester, MN, United States
Institute of Nuclear Medicine, Middlesex Hospital, London, United Kingdom
Klinik für Nuklearmedizin, Universität Würzburg, Würzburg, Germany
Service de Médecine Nucléaire, Hôpital de Brabois, Vandoeuvre, France
Scarabino, T., Nemore, F., Giannatempo, G.M., Risonanza magnetica 3.0 Tesla (2003) Rivista di Neuroradiologia, 16, pp. 314-315
Frayne, R., Goodyear, B.G., Dickhoff, P., Magnetic resonance imaging at 3.0 tesla: Challenges and advantages in clinical neurological imaging (2003) Investigative Radiology, 38, pp. 385-402
Takahashi, M., Uematsu, H., Hatabu, H., MR imaging at high magnetic fields (2003) Eur J Radiol, 46, pp. 45-52
Wang, J., Alsop, D.C., Li, L., Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 T and 4.0 Tesla (2002) Magn Reson Med, 48, pp. 242-254
Anagnostopoulos, C., Harbinson, M., Kelion, A., Kundley, K., Loong, C. Y., Notghi, A., Procedure guidelines for radionuclide myocardial perfusion imaging (2004) Heart, 90 (1 SUPPL.), pp. i1-1
ESC Guidelines for Exercise Testing
American Guidelines (The ACC/AHA Exercise Testing Guidelines)
Society of Nuclear Medicine Procedure Guideline for Myocardial Perfusion Imaging
American Society of Nuclear Cardiology: Imaging Guidelines for Nuclear Cardiology Procedures
Grunwald, A. M., Watson, D. D., Holzgrefe Jr., H. H., Irving, J. F., Beller, G. A., Myocardial thallium-201 kinetics in normal and ischaemic myocardium (1981) Circulation, 64, pp. 610-618
Ingwall, J. S., Kramer, M., Kloner, N. M., Thallium accumulation: Differentiation between reversible and irreversible myocardial injury (1979) Circulation, 59, p. 678. , abstract
Dilsizian, V., Rocco, T. P., Freedman, N. M., Leon, M. B., Bonow, R. O., Enhanced detection of ischaemic but viable myocardium by the reinjection of thallium after stress-redistribution imaging (1990) N Engl J Med, 323, pp. 141-146
Van Eck-Smit, B. L., Van Der Wall, E. E., Zwinderman, A. H., Pauwels, E. K., Clinical value of immediate thallium-201 reinjection imaging for the detection of ischaemic heart disease (1995) Eur Heart J, 16, pp. 410-420
Li, Q. S., Solot, G., Frank, T. L., Wagner, H. N. J., Becker, L. C., Myocardial redistribution of technetium-99m-methoxyisobutyl isonitrile (SESTAMIBI) (1990) J Nucl Med, 31, pp. 1069-1076
Jain, D., Wackers, F. J., Mattera, J., McMahon, M., Sinusas, A. J., Zaret, B. L., Biokinetics of technetium-99m-tetrofosmin: Myocardial perfusion imaging agent: Implications for a one-day imaging protocol (1993) J Nucl Med, 34, pp. 1254-1259
M nch, G., Neverve, J., Matsunari, I., Schr ter, G., Schwaiger, M., Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease (1997) J Nucl Med, 38, pp. 428-432
Maurea, S., Cuocolo, A., Soricelli, A., Castelli, L., Nappi, A., Squame, F., Enhanced detection of viable myocardium by technetium-99m-MIBI imaging after nitrate administration in chronic coronary artery disease (1995) J Nucl Med, 36, pp. 1945-1952
Thorley, P. J., Bloomer, T. N., Sheard, K. L., Sivananthan, U. M., The use of GTN to improve the detection of ischaemic myocardium using Tc-99m-tetrofosmin (1996) Nucl Med Commun, 17, pp. 669-674
Vanzetto, G., Fagret, D., Pasqualini, R., Mathieu, J. P., Chossat, F., Machecourt, J., Biodistribution, dosimetry, and safety of myocardial perfusion imaging agent 99mTcN-NOET in healthy volunteers (2000) J Nucl Med, 41, pp. 141-148
Cuocolo, A., Rubini, G., Acampa, W., Nicolai, E., Florimonte, L., Digiovine, G., Technetium 99m furifosmin regional myocardial uptake in patients with previous myocardial infarction: Relation to thallium-201 activity and left ventricular function (2000) J Nucl Cardiol, 7, pp. 235-241
[CD97] Council Directive 97/43/Euratom of 30 June 1997 on health protection of individuals against the dangers of ionizing radiation in relation to medical exposure, and repealing Directive 84/466/Euratom (1997) Official J Eur Commun, 180 L, pp. 22-27
Heo, J., Powers, J., Iskandrian, A. E., Exercise-rest same-day SPECT sestamibi imaging to detect coronary artery disease (1997) J Nucl Med, 38, pp. 200-203
Garcia, E. V., Cooke, C. D., Van Train, K. F., Folks, R., Peifer, J., DePuey, E. G., Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi (1990) Am J Cardiol, 66, pp. 23E-31E
Radiation dose to patients from radiopharmaceuticals (1998) Annals of ICRP, 28, p. 3. , ICRP Publication 80. Oxford: Pergamon Press
1990 Recommendations of the ICRP (1992) Annals of ICRP, 21, pp. 1-3. , ICRP Publication 60. Oxford: Pergamon Press
Piepsz, A., Hahn, K., Roca, I., Ciofetta, G., Toth, G., Gordon, I., A radiopharmaceuticals schedule for imaging in paediatrics (1990) Eur J Nucl Med, 17 (3-4), pp. 127-129. , Paediatric Task Group European Association Nuclear Medicine
Strahlenexposition von Personen durch uklearmedizinisch untersuchte Patienten (1999) Empfehlungen und Stellungnahmen der Strahlenschutzkommission 1998, , Gumprecht D, Heller H, editors. Bonn
(1998) Radiation Protection 100. Guidance for Protection of Unborn Children and Infants Irradiated Due to Parental Medical Exposures, 100. , http: //europa. eu. int/comm/environment/pubs/nuclear. htm#, European Commission on-line publication catalogue
Clinical competence statement on exercise stress testing. AHA/ACC Task Force Report (2000) J Am Coll Cardiol, 36, pp. 1441-1453
Guidelines for clinical use of cardiac radionuclide imaging. AHA/ACC Task Force Report (1995) Circulation, 91, pp. 1278-1303
Pennell, D. J., Mavrogeni, S. I., Forbat, S. M., Karwatowski, S. P., Underwood, S. R., Adenosine combined with dynamic exercise for myocardial perfusion imaging (1995) J Am Coll Cardiol, 25, pp. 1300-1309
Samady, H., Wackers, F. J., Joska, T., Zaret, B., Jain, D., Pharmacologic stress perfusion imaging with adenosine: Role of simultaneous low-level treadmill exercise (2002) J Nucl Cardiol, 9, pp. 188-196
Thomas, G. S., Prill, N. V., Majmundar, H., Fabrizi, R. R., Thomas, J. J., Hayashida, C., Treadmill exercise during adenosine infusion is safe, results in fewer adverse reactions, and improves myocardial perfusion image quality (2000) J Nucl Cardiol, 7, pp. 439-446
Treuth, M. G., Reyes, G. A., He, Z. X., Cwajg, E., Mahmarian, J. J., Verani, M. S., Tolerance and diagnostic accuracy of an abbreviated adenosine infusion for myocardial scintigraphy: A randomized prospective study (2001) J Nucl Cardiol, 8, pp. 548-554
Cerqueira, M. D., Verani, M. S., Schwaiger, M., Heo, J., Iskandrian, A. S., Safety profile of adenosine stress perfusion imaging
results from the Adenoscan Multicenter Trial Registry (1994) J Am Coll Cardiol, 23, pp. 384-390
Lette, J., Tatum, J. L., Fraser, S., Miller, D. D., Waters, D. D., Heller, G., Safety of dipyridamole testing in 73, 806 patients: The Multicenter Dipyridamole Safety study (1994) J Nucl Cardiol, 2, pp. 3-17
McNeill, A. J., Fioretti, P. M., El-Said, S. M., Salustri, A., Forster, T., Roelandt, J. R., Enhanced sensitivity for detection of coronary artery disease by addition of atropine to dobutamine stress echocardiography (1992) Am J Cardiol, 70, pp. 41-46
Hicks, R. J., Myocardial perfusion scintigraphy techniques using single photon radiotracers (1998) Nuclear Medicine in Diagnosis and Treatment. 2nd Ed., pp. 1333-1351. , Murray E, editor. New York: Churchill Livingstone
Rocco, T. P., Dilsizian, V., McKusick, K. A., Fischman, A. J., Boucher, C. A., Strauss, H. W., Comparison of thallium redistribution with rest "reinjection" imaging for detection of viable myocardium (1990) Am J Cardiol, 66, pp. 158-163
Heo, J., Kegel, J., Iskandrian, A. S., Cave, V., Iskandrian, B. B., Comparison of same-day protocols using technetium-99m-sestamibi myocardial imaging (1992) J Nucl Med, 33, pp. 186-191
Van Dongen, A. J., Van Rijk, P. P., Minimizing liver, bowel, and gastric activity in myocardial perfusion SPECT (2000) J Nucl Med, 41, pp. 1315-1317
Hurwitz, G. A., Clark, E. M., Slomka, P. J., Siddiq, S. K., Investigation of measures to reduce interfering abdominal activity on rest myocardial images with Tc-99m sestamibi (1993) Clin Nucl Med, 18, pp. 735-741
Berman, D. S., Kiat, H. S., Van Train, K. F., Germano, G., Maddahi, J., Friedman, J. D., Myocardial perfusion imaging with technetium-99m-sestamibi: Comparative analysis of available imaging protocols (1994) J Nucl Med, 354, pp. 681-688
Segall, G. M., Davis, M. J., Prone versus supine thallium myocardial SPECT: A method to decrease artefactual inferior wall defects (1989) J Nucl Med, 30, pp. 548-555
Strauss, H. W., Miller, D. D., Wittry, M. D., Cerqueira, M. D., Garcia, E. V., Iskandrian, A. S., Procedure guideline for myocardial perfusion imaging (1998) J Nucl Med, 39, pp. 918-923. , Society of Nuclear Medicine
Eisner, R. L., Nowak, D. J., Pettigrew, R., Fajman, W., Fundamentals of 180-degree acquisition and reconstruction in SPECT imaging (1986) J Nucl Med, 27, pp. 1717-1728
DePuey, E. G., Garcia, E., Borges-Neto, S., Jain, D., Fiacro, E., Nichols, K., Updated imaging guidelines for nuclear cardiology procedures, part 1 (2001) J Nucl Cardiol, 8, pp. G1-58
Quality Control of Nuclear Medicine Instruments 1991, , IAEA TECDOC-602. ISSN 1011-4289, International Atomic Energy Agency, Vienna
(1999) Society of Nuclear Medicine Procedure Guideline for General Imaging, Version 2. 0, , http: //www. snm. org, Society of Nuclear Medicine
Report 86 Quality control of gamma camera systems (2003) Institute of Physics in Engineering and Medicine, , Bolster A, editor. ISBN 1 903613 13 2
O'Connor, M. K., Hung, J. C. Y., Instrumentation quality control (1996) Mayo Clinic Manual of Nuclear Medicine, pp. 1-57. , O'Connor MK, editor. New York: Churchill Livingstone
(2003) IAEA Quality Control Atlas for Scintillation Systems, , (compiler/author: E. Busemann Sokole). ISBN 92-0-101303-5. International Atomic Energy Agency, Vienna
(2001) NEMA NU1-2001 Performance Measurements of Scintillation Cameras, , Standards publication, National Electrical Manufacturer's Association
Busemann Sokole, E., Measurement of collimator hole angulation and camera head tilt for slant and parallel hole collimators used in SPECT (1987) J Nucl Med, 28, pp. 1592-1598
Bracewell, R. N., Riddle, A. C., Inversion of fan-beam scans in radioastronomy (1967) Astrophys J, 150, pp. 427-438
Hutton, B. F., Hudson, H. M., Beekman, F. J., A clinical perspective of accelerated statistical reconstruction (1997) Eur J Nucl Med, 24, pp. 797-808
Hudson, H. M., Larkin, R. S., Accelerated image reconstruction using ordered subsets of projection data (1994) IEEE Trans Nucl Sci, 13, pp. 601-609
Llacer, J., Velkerov, E., Feasible images and practical stopping rules for iterative algorithms in emission tomography (1989) IEEE Trans Med Imag, 8, pp. 186-193
Butterworth, S., On the theory of filter amplifiers (1930) Exp Wirel Wirel Eng, 7, pp. 536-541
Links, J. M., Jeremy, R. W., Dyer, S. M., Frank, T. L., Becker, L. C., Wiener filtering improves quantification of regional myocardial perfusion with thallium-201 SPECT (1990) J Nucl Med, 31, pp. 1230-1236
Miller, T. R., Sampathkumaran, K. S., Design and application of finite impulse response digital filters (1982) Eur J Nucl Med, 7, pp. 22-27
Germano, G., Chua, T., Kavanagh, P. B., Kiat, H., Berman, D. S., Detection and correction of patient motion in dynamic and static myocardial SPECT using a multi-detector camera (1993) J Nucl Med, 34, pp. 1349-1355
Matsumoto, N., Berman, D. S., Kavanagh, P. B., Gerlach, J., Hayes, S. W., Lewin, H. C., Quantitative assessment of motion artifacts and validation of a new motion-correction program for myocardial perfusion SPECT (2001) J Nucl Med, 42, pp. 687-694
Friedman, J., Van Train, K., Maddahi, J., Rozanski, A., Prigent, F., Bietendorf, J., "Upward creep" of the heart: A frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT (1989) J Nucl Med, 30, pp. 1718-1722
Germano, G., Kavanagh, P. B., Chen, J., Waechter, P., Su, H. T., Kiat, H., Operator-less processing of myocardial perfusion SPECT studies (1995) J Nucl Med, 36, pp. 2127-2132
Slomka, P. J., Hurwitz, G. A., Stephenson, J., Cradduck, T., Automated alignment and sizing of myocardial stress and rest scans to three-dimensional normal templates using an image registration algorithm (1995) J Nucl Med, 36, pp. 1115-1122
Choi, J. Y., Lee, K. H., Kim, S. J., Kim, S. E., Kim, B. T., Lee, S. H., Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT (1998) J Nucl Cardiol, 5, pp. 395-401
Germano, G., Berman, D. S., Acquisition and processing for gated perfusion SPECT: Technical aspects (1999) Clinical Cardiac SPECT, pp. 93-113. , Germano G, Berman DS, editors. Armonk, NY: Futura Publishing Company
Manrique, A., Faraggi, M., Vera, P., Vilain, D., Lebtahi, R., Cribier, A., 201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: Comparison with equilibrium radionuclide angiography (1999) J Nucl Med, 40, pp. 805-809
De Puey, E. G., Parmett, S., Ghesani, M., Rozanski, A., Nichols, K., Salensky, H., Comparison of Tc-99m sestamibi and Tl-201 gated perfusion SPECT (1999) J Nucl Cardiol, 6, pp. 278-285
Sharir, T., Germano, G., Kang, X., Cohen, I., Friedman, J. D., Berman, D. S., Prognostic value of post-stress left ventricular volume and ejection fraction by gated myocardial perfusion single photon emission computed tomography in women: Gender related differences in normal limits and outcome (2002) Circulation, 106 (19), pp. II-523. , abstract
Smanio, P. E., Watson, D. D., Segalla, D. L., Vinson, E. L., Smith, W. H., Beller, G. A., Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging (1997) J Am Coll Cardiol, 30, pp. 1687-1692
Lima, R. S., Watson, D. D., Goode, A. R., Siadaty, M. S., Ragosta, M., Beller, G. A., Incremental value of combined perfusion and function over perfusion alone by gated SPECT myocardial perfusion imaging for detection of severe three-vessel coronary artery disease (2003) J Am Coll Cardiol, 42, pp. 64-70
Prvulovich, E. M., Lonn, A. H., Bomanji, J. B., Jarritt, P. H., Ell, P. J., Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease (1997) Eur J Nucl Med, 24, pp. 266-275
Kluge, R., Sattler, B., Seese, A., Knapp, W. H., Attenuation correction by simultaneous emission-transmission myocardial single-photon emission tomography using technetium-99m labelled radiotracer: Impact on diagnostic accuracy (1997) Eur J Nucl Med, 24, pp. 1107-1114
Hendel, R. C., Berman, D. S., Cullom, S. J., Follansbee, W., Heller, G. V., Kiat, H., Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging (1999) Circulation, 99, pp. 2742-2749
Matsunari, I., Boning, G., Ziegler, S. I., Nekolla, S. G., Stollfuss, J. C., Kosa, I., Attenuation corrected Tc-99m-tetrofosmin single-photon emission computed tomography in the detection of viable myocardium: Comparison with positron emission tomography using 18F-fluorodeoxyglucose (1998) J Am Coll Cardiol, 32, pp. 927-935
Chouraqui, P., Livschitz, S., Sharir, T., Wainer, N., Wilk, M., Moalem, I., Evaluation of an attenuation correction method for thallium-201 myocardial perfusion tomographic imaging of patients with low likelihood of coronary artery disease (1998) J Nucl Cardiol, 5, pp. 369-377
Rigo, P., Van Boxem, P., Foulon, J., Safi, M., Engdahl, J., Links, J., Quantitative evaluation of a comprehensive motion, resolution, and attenuation correction program: Initial experience (1998) J Nucl Cardiol, 5, pp. 458-468
Vidal, R., Buvat, I., Darcourt, J., Migneco, O., Desvignes, P., Baudouy, M., Impact of attenuation correction by simultaneous emission/transmission tomography on visual assessment of 201Tl myocardial perfusion images (1999) J Nucl Med, 40, pp. 1301-1309
Ficaro, E. P., Wackers, F. J. T., Should SPET attenuation correction be more widely employed in routine clinical practice? (2002) Eur J Nucl Med Mol Imaging, 29, pp. 409-415
Hendel, R. C., Corbett, J. R., Cullom, S. J., DePuey, E. G., Garcia, E. V., Bateman, T. M., The value and practice of attenuation correction for myocardial perfusion SPECT imaging: A joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine (2002) J Nucl Cardiol, 9, pp. 135-143
Corbett, R. J., Ficaro, E. P., Clinical review of attenuation-corrected cardiac SPECT (1999) J Nucl Cardiol, 6, pp. 54-68
O'Connor, M. K., Kemp, B., Anstett, F., Christian, P., Ficaro, E. P., Frey, E., A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models (2002) J Nucl Cardiol, 9, pp. 361-376
Zaidi, H., Koral, K. F., Scatter modelling and compensation in emission tomography (2004) Eur J Nucl Med Mol Imaging, 31, pp. 761-782
Links, J. M., Becker, L. C., Rigo, P., Taillefer, R., Hanelin, L., Anstett, F., Combined corrections for attenuation, depth-dependent blur, and motion in cardiac SPECT: A multicenter trial (2000) J Nucl Cardiol, 7, pp. 414-425
Narayanan, M. V., King, M. A., Pretorius, P. H., Dahlberg, S. T., Spencer, F., Simon, E., Human-observer receiver-operating characteristic evaluation of attenuation, scatter, and resolution compensation strategies for 99mTc myocardial perfusion imaging (2003) J Nucl Med, 44, pp. 1725-1734
Wackers, F. J. T., Attenuation compensation of cardiac SPECT: A critical look at a confusing world (2002) J Nucl Cardiol, 9, pp. 438-440
Gallowitsch, H. J., Sykora, J., Mikosch, P., Kresnik, E., Unterweger, O., Molnar, M., Attenuation-corrected thallium-201 single-photon emission tomography using a gadolinium-153 moving line source: Clinical value and the impact of attenuation correction on the extent and severity of perfusion abnormal-ities (1998) Eur J Nucl Med, 25, pp. 220-228
Almquist, H., Arheden, H., Arvidsson, A. H., Pahlm, O., Palmer, J., Clinical implication of down-scatter in attenuation-corrected myocardial SPECT (1999) J Nucl Cardiol, 6, pp. 406-411
Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association (2002) Circulation, 105, pp. 539-542
Shehata, A. R., Ahlberg, A. W., White, M. P., Russell, A., Fleming, I. A., Levine, M. G., Dipyridamole-dobutamine stress with Tc-99m sestamibi tomographic myocardial perfusion imaging (1998) Am J Cardiol, 82, pp. 520-523
Van Train, K. F., Alreeda, J., Garcia, E. V., Cooke, C. D., Maddahi, J., Kiat, H., Quantitative same-day rest-stress technetium-99m-sestamibi SPECT: Definition and validation of stress normal limits and criteria for abnormality (1993) J Nucl Med, 34, pp. 1494-1502
Berman, D. S., Kang, X., Van Train, K. F., Lewin, H. C., Cohen, I., Areeda, J., Comparative prognostic value of automatic quantitative analysis versus semiquantitative visual analysis of exercise myocardial perfusion single-photon emission computed tomography (1998) J Am Coll Cardiol, 32, pp. 1987-1995
Sharir, T., Berman, D. S., Waechter, P. B., Areeda, J., Kavanagh, P. B., Gerlach, J., Quantitative analysis of regional motion and thickening by gated myocardial perfusion SPECT: Normal heterogeneity and criteria for abnormality (2001) J Nucl Med, 42, pp. 1630-1638
McClellan, J. R., Travin, M. I., Herman, S. D., Baron, J. I., Golub, R. J., Gallagher, J. J., Prognostic importance of scintigraphic left ventricular cavity dilation during intravenous dipyridamole technetium-99m sestamibi myocardial tomographic imaging in predicting coronary events (1997) Am J Cardiol, 79, pp. 600-605
Mazzanti, M., Germano, G., Kiat, H., Kavanagh, P. B., Alexanderson, E., Friedman, J. D., Identification of severe and extensive coronary artery disease by automatic measurement of transient ischemic dilation of the left ventricle in dual-isotope myocardial perfusion SPECT (1996) J Am Coll Cardiol, 27, pp. 1612-1620
Ioannidis, J. P., Trikalinos, T. A., Danias, P. G., Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: A meta-analysis (2002) J Am Coll Cardiol, 39, pp. 2059-2068
Tadamura, E., Kudoh, T., Motooka, M., Inubushi, M., Shirakawa, S., Hattori, N., Assessment of regional and global left ventricular function by reinjection Tl-201 and rest Tc-99m sestamibi ECG-gated SPECT: Comparison with three-dimensional magnetic resonance imaging (1999) J Am Coll Cardiol, 33, pp. 991-997
Bavelaar-Croon, C. D., Kayser, H. W., Van Der Wall, E. E., De Roos, A., Dibbets-Schneider, P., Pauwels, E. K., Left ventricular function: Correlation of quantitative gated SPECT and MR imaging over a wide range of values (2000) Radiology, 217, pp. 572-575
Yoshioka, J., Hasegawa, S., Yamaguchi, H., Tokita, N., Paul, A. K., Xiuli, M., Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic-gated 99mTc-tetrofosmin myocardial SPECT (1999) J Nucl Med, 40, pp. 1693-1698
Acampa, W., Cuocolo, A., Petretta, M., Bruno, A., Castellani, M., Finzi, A., Tetrofosmin imaging in the detection of myocardial viability in patients with previous myocardial infarction: Comparison with sestamibi and Tl-201 scintigraphy (2002) J Nucl Cardiol, 9, pp. 33-40
Peix, A., Lopez, A., Ponce, F., Morales, J., De La Vega, A. R., Chesa, C. S., Enhanced detection of reversible myocardial hypoperfusion by technetium 99m-tetrofosmin imaging and first-pass radionuclide angiography after nitroglycerin administration (1998) J Nucl Cardiol, 5, pp. 469-476
Greco, C., Ciavolella, M., Tanzilli, G., Sinatra, R., Macrina, F., Schillaci, O., Preoperative identification of viable myocardium: Effectiveness of nitroglycerine-induced changes in myocardial sestamibi uptake (1998) Cardiovasc Surg, 6, pp. 149-155
Cerqueira, M. D., The user friendly nuclear cardiology report: What needs to be considered and what needs to be included (1996) J Nucl Cardiol, 3, pp. 350-356
Pennell, D. J., Prvulovich, E., Image interpretation (1995) Nuclear Cardiology, pp. 56-79. , Ell PJ, editor. London: British Nuclear Medicine Society
Standardisation of cardiac tomographic imaging (1992) Circulation, 86, pp. 338-339
Candell-Riera, J., Santana-Boado, C., Bermejo, B., Armadans, L., Castell, J., Casans, I., Interhospital observer agreement on interpretation of exercise myocardial Tc-99m-tetrofosmin SPECT studies (2001) J Nucl Cardiol, 8, pp. 49-57
Knuuti, J., Schelbert, H. R., Bax, J. J., The need for standardisation of cardiac FDG PET imaging in the evaluation of myocardial viability in patients with chronic ischaemic left ventricular dysfunction (2002) Eur J Nucl Med Mol Imaging, 29, pp. 1257-1266
Knuuti, M. J., Nuutila, P., Ruotsalainen, U., Saraste, M., Harkonen, R., Ahonen, A., Euglycemic hyperinsulinemic clamp and oral glucose load in stimulating myocardial glucose utilization during positron emission tomography (1992) J Nucl Med, 33, pp. 1255-1262
Berry, J. J., Baker, J. A., Pieper, K. S., Hanson, M. W., Hoffman, J. M., Coleman, R. E., The effect of metabolic milieu on cardiac PET imaging using fluorine-18-deoxyglucose and nitrogen-13-ammonia in normal volunteers (1991) J Nucl Med, 32, pp. 1518-1525
Knuuti, M. J., Yki-Jarvinen, H., Voipio-Pulkki, L. M., Maki, M., Ruotsalainen, U., Harkonen, R., Enhancement of myocardial [fluorine-18] fluorodeoxyglucose uptake by a nicotinic acid derivative (1994) J Nucl Med, 35, pp. 989-998
Schinkel, A. F., Bax, J. J., Valkema, R., Elhendy, A., Van Domburg, R. T., Vourvouri, E. C., Effect of diabetes mellitus on myocardial 18F-FDG SPECT using acipimox for the assessment of myocardial viability (2003) J Nucl Med, 44, pp. 877-883
Schroder, O., Hor, G., Hertel, A., Baum, R. P., Combined hyperinsulinaemic glucose clamp and oral acipimox for optimizing metabolic conditions during 18F-fluorodeoxyglucose gated PET cardiac imaging: Comparative results (1998) Nucl Med Commun, 19, pp. 867-874
Lewis, P., Nunan, T., Dynes, A., Maisey, M., The use of low-dose intravenous Insulin in clinical myocardial F-18 FDG PET scanning (1996) Clin Nucl Med, 21, pp. 15-18
McCord, M. E., Bacharach, S. L., Bonow, R. O., Dilsizian, V., Cuocolo, A., Freedman, N., Misalignment between PET transmission and emission scans: Its effect on myocardial imaging (1992) J Nucl Med, 33, pp. 1209-1214
Porenta, G., Kuhle, W., Czernin, J., Ratib, O., Brunken, R. C., Phelps, M. E., Semiquantitative assessment of myocardial blood flow and viability using polar map displays of cardiac PET images (1992) J Nucl Med, 33, pp. 1628-1636
Nekolla, S., Miethaner, C., Nguyen, N., Ziegler, S., Schwaiger, M., Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography (1998) Eur J Nucl Med, 25, pp. 1313-1321
Bergmann, S. R., Herrero, P., Markham, J., Weinheimer, C. J., Walsh, M. N., Non-invasive quantitation of myocardial blood flow in human subjects with oxygen-15 labelled water and positron emission tomography (1989) J Am Coll Cardiol, 14, pp. 639-652
Choi, Y., Huang, S. C., Hawkins, R. A., Kuhle, W. G., Dahlbom, M., Hoh, C. K., A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic PET (1993) J Nucl Med, 34, pp. 488-497
Hutchins, G., Schwaiger, M., Rosenspire, K., Krivokapich, J., Schelbert, H., Kuhl, D., Noninvasive quantification of regional myocardial blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging (1990) J Am Coll Cardiol, 15, p. 1032
Iida, H., Kanno, I., Takahashi, A., Miura, S., Murakami, M., Takahashi, K., Measurement of absolute myocardial blood flow with H2 15O and dynamic positron emission tomography. Strategy for quantification in relation to the partial-volume effect (1988) Circulation, 78, pp. 104-115
Muzik, O., Beanlands, R., Wolfe, E., Hutchins, G. D., Schwaiger, M., Automated region definition for cardiac nitrogen-13-ammonia PET imaging (1993) J Nucl Med, 34, pp. 336-344
Di Carli, M., Czernin, J., Hoh, C. K., Gerbaudo, V. H., Brunken, R. C., Huang, S. C., Relation among stenosis severity, myocardial blood flow, and flow reserve in patients with coronary artery disease (1995) Circulation, 91, pp. 1944-1951
Uren, N. G., Melin, J. A., De-Bruyne, B., Wijns, W., Baudhuin, T., Camici, P. G., Relation between myocardial blood flow and the severity of coronary-artery stenosis (1994) N Engl J Med, 330, pp. 1782-1788
Gropler, R. J., Lee, K. J., Moerlein, S. M., Siegel, B. A., Geltman, E. M., Regional variation in myocardial accumulation of 18F- fluorodeoxyglucose in fasted normal subjects (1990) J Am Coll Cardiol, 15, pp. 81A
Choi, Y., Hawkins, R. A., Brunken, R. C., Huang, S. C., Kuhle, W. G., Chen, K., Evaluation of regional heterogeneity of myocardial glucose metabolism in normal humans using dynamic FDG-PET (1991) J Nucl Med, 32, p. 938
Maes, A., Flameng, W., Borgers, M., Nuyts, J., Ausma, J., Bormans, G., Regional myocardial blood flow, glucose utilization and contractile function before and after revascularization and ultrastructural findings in patients with chronic coronary artery disease (1995) Eur J Nucl Med, 22, pp. 1299-1305
Mesotten, L., Maes, A., Herregods, M. C., Desmet, W., Nuyts, J., Van De Werf, F., PET "reversed mismatch pattern" early after acute myocardial infarction: Follow-up of flow, metabolism and function (2001) Eur J Nucl Med, 28, pp. 466-471
Di Carli, M. F., Asgarzadie, F., Schelbert, H. R., Brunken, R. C., Laks, H., Phelps, M. E., Quantitative relation between myocardial viability and improvement in heart failure symptoms after revascularization in patients with ischemic cardiomyopathy (1995) Circulation, 92, pp. 3436-3444
Bax, J. J., Poldermans, D., Elhendy, A., Cornel, J. H., Boersma, E., Rambaldi, R., Improvement of left ventricular ejection fraction, heart failure symptoms and prognosis after revascularization in patients with chronic coronary artery disease and viable myocardium detected by dobutamine stress echocardiography (1999) J Am Coll Cardiol, 34, pp. 163-169
Vom Dahl, J., Altehoefer, C., Sheehan, F. H., Buechin, P., Uebis, R., Messmer, B. J., Recovery of regional left ventricular dysfunction after coronary revascularization. Impact of myocardial viability assessed by nuclear imaging and vessel patency at follow-up angiography (1996) J Am Coll Cardiol, 28, pp. 948-958
Gambhir, S. S., Schwaiger, M., Huang, S. C., Krivokapich, J., Schelbert, H. R., Nienaber, C. A., Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose (1989) J Nucl Med, 30, pp. 359-366
Blanksma, P. K., Willemsen, A. T., Meeder, J. G., De Jong, R. M., Anthonio, R. L., Pruim, J., Quantitative myocardial mapping of perfusion and metabolism using parametric polar map displays in cardiac PET (1995) J Nucl Med, 36, pp. 153-158
Grunwald, A.M., Watson, D.D., Holzgrefe Jr., H.H., Irving, J.F., Beller, G.A., Myocardial thallium-201 kinetics in normal and ischaemic myocardium (1981) Circulation, 64, pp. 610-618
Ingwall, J.S., Kramer, M., Kloner, N.M., Thallium accumulation: Differentiation between reversible and irreversible myocardial injury (1979) Circulation, 59, p. 678. , abstract
Van Eck-Smit, B.L., Van Der Wall, E.E., Zwinderman, A.H., Pauwels, E.K., Clinical value of immediate thallium-201 reinjection imaging for the detection of ischaemic heart disease (1995) Eur Heart J, 16, pp. 410-420
Münch, G., Neverve, J., Matsunari, I., Schröter, G., Schwaiger, M., Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease (1997) J Nucl Med, 38, pp. 428-432
Thorley, P.J., Bloomer, T.N., Sheard, K.L., Sivananthan, U.M., The use of GTN to improve the detection of ischaemic myocardium using Tc-99m-tetrofosmin (1996) Nucl Med Commun, 17, pp. 669-674
Garcia, E.V., Cooke, C.D., Van Train, K.F., Folks, R., Peifer, J., DePuey, E.G., Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi (1990) Am J Cardiol, 66, pp. 23E-31E
Pennell, D.J., Mavrogeni, S.I., Forbat, S.M., Karwatowski, S.P., Underwood, S.R., Adenosine combined with dynamic exercise for myocardial perfusion imaging (1995) J Am Coll Cardiol, 25, pp. 1300-1309
Thomas, G.S., Prill, N.V., Majmundar, H., Fabrizi, R.R., Thomas, J.J., Hayashida, C., Treadmill exercise during adenosine infusion is safe, results in fewer adverse reactions, and improves myocardial perfusion image quality (2000) J Nucl Cardiol, 7, pp. 439-446
Treuth, M.G., Reyes, G.A., He, Z.X., Cwajg, E., Mahmarian, J.J., Verani, M.S., Tolerance and diagnostic accuracy of an abbreviated adenosine infusion for myocardial scintigraphy: A randomized prospective study (2001) J Nucl Cardiol, 8, pp. 548-554
Cerqueira, M.D., Verani, M.S., Schwaiger, M., Heo, J., Iskandrian, A.S., Safety profile of adenosine stress perfusion imaging
McNeill, A.J., Fioretti, P.M., El-Said, S.M., Salustri, A., Forster, T., Roelandt, J.R., Enhanced sensitivity for detection of coronary artery disease by addition of atropine to dobutamine stress echocardiography (1992) Am J Cardiol, 70, pp. 41-46
Hicks, R.J., Myocardial perfusion scintigraphy techniques using single photon radiotracers (1998) Nuclear Medicine in Diagnosis and Treatment. 2nd Ed., pp. 1333-1351. , Murray E, editor. New York: Churchill Livingstone
Rocco, T.P., Dilsizian, V., McKusick, K.A., Fischman, A.J., Boucher, C.A., Strauss, H.W., Comparison of thallium redistribution with rest "reinjection" imaging for detection of viable myocardium (1990) Am J Cardiol, 66, pp. 158-163
Van Dongen, A.J., Van Rijk, P.P., Minimizing liver, bowel, and gastric activity in myocardial perfusion SPECT (2000) J Nucl Med, 41, pp. 1315-1317
Hurwitz, G.A., Clark, E.M., Slomka, P.J., Siddiq, S.K., Investigation of measures to reduce interfering abdominal activity on rest myocardial images with Tc-99m sestamibi (1993) Clin Nucl Med, 18, pp. 735-741
Berman, D.S., Kiat, H.S., Van Train, K.F., Germano, G., Maddahi, J., Friedman, J.D., Myocardial perfusion imaging with technetium-99m-sestamibi: Comparative analysis of available imaging protocols (1994) J Nucl Med, 354, pp. 681-688
Segall, G.M., Davis, M.J., Prone versus supine thallium myocardial SPECT: A method to decrease artefactual inferior wall defects (1989) J Nucl Med, 30, pp. 548-555
Strauss, H.W., Miller, D.D., Wittry, M.D., Cerqueira, M.D., Garcia, E.V., Iskandrian, A.S., Procedure guideline for myocardial perfusion imaging (1998) J Nucl Med, 39, pp. 918-923. , Society of Nuclear Medicine
Eisner, R.L., Nowak, D.J., Pettigrew, R., Fajman, W., Fundamentals of 180-degree acquisition and reconstruction in SPECT imaging (1986) J Nucl Med, 27, pp. 1717-1728
DePuey, E.G., Garcia, E., Borges-Neto, S., Jain, D., Fiacro, E., Nichols, K., Updated imaging guidelines for nuclear cardiology procedures, part 1 (2001) J Nucl Cardiol, 8, pp. G1-58
O'Connor, M.K., Hung, J.C.Y., Instrumentation quality control (1996) Mayo Clinic Manual of Nuclear Medicine, pp. 1-57. , O'Connor MK, editor. New York: Churchill Livingstone
Bracewell, R.N., Riddle, A.C., Inversion of fan-beam scans in radioastronomy (1967) Astrophys J, 150, pp. 427-438
Hutton, B.F., Hudson, H.M., Beekman, F.J., A clinical perspective of accelerated statistical reconstruction (1997) Eur J Nucl Med, 24, pp. 797-808
Hudson, H.M., Larkin, R.S., Accelerated image reconstruction using ordered subsets of projection data (1994) IEEE Trans Nucl Sci, 13, pp. 601-609
Links, J.M., Jeremy, R.W., Dyer, S.M., Frank, T.L., Becker, L.C., Wiener filtering improves quantification of regional myocardial perfusion with thallium-201 SPECT (1990) J Nucl Med, 31, pp. 1230-1236
Miller, T.R., Sampathkumaran, K.S., Design and application of finite impulse response digital filters (1982) Eur J Nucl Med, 7, pp. 22-27
Slomka, P.J., Hurwitz, G.A., Stephenson, J., Cradduck, T., Automated alignment and sizing of myocardial stress and rest scans to three-dimensional normal templates using an image registration algorithm (1995) J Nucl Med, 36, pp. 1115-1122
Choi, J.Y., Lee, K.H., Kim, S.J., Kim, S.E., Kim, B.T., Lee, S.H., Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT (1998) J Nucl Cardiol, 5, pp. 395-401
De Puey, E.G., Parmett, S., Ghesani, M., Rozanski, A., Nichols, K., Salensky, H., Comparison of Tc-99m sestamibi and Tl-201 gated perfusion SPECT (1999) J Nucl Cardiol, 6, pp. 278-285
Smanio, P.E., Watson, D.D., Segalla, D.L., Vinson, E.L., Smith, W.H., Beller, G.A., Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging (1997) J Am Coll Cardiol, 30, pp. 1687-1692
Lima, R.S., Watson, D.D., Goode, A.R., Siadaty, M.S., Ragosta, M., Beller, G.A., Incremental value of combined perfusion and function over perfusion alone by gated SPECT myocardial perfusion imaging for detection of severe three-vessel coronary artery disease (2003) J Am Coll Cardiol, 42, pp. 64-70
Prvulovich, E.M., Lonn, A.H., Bomanji, J.B., Jarritt, P.H., Ell, P.J., Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease (1997) Eur J Nucl Med, 24, pp. 266-275
Hendel, R.C., Berman, D.S., Cullom, S.J., Follansbee, W., Heller, G.V., Kiat, H., Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging (1999) Circulation, 99, pp. 2742-2749
Ficaro, E.P., Wackers, F.J.T., Should SPET attenuation correction be more widely employed in routine clinical practice? (2002) Eur J Nucl Med Mol Imaging, 29, pp. 409-415
Hendel, R.C., Corbett, J.R., Cullom, S.J., DePuey, E.G., Garcia, E.V., Bateman, T.M., The value and practice of attenuation correction for myocardial perfusion SPECT imaging: A joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine (2002) J Nucl Cardiol, 9, pp. 135-143
Corbett, R.J., Ficaro, E.P., Clinical review of attenuation-corrected cardiac SPECT (1999) J Nucl Cardiol, 6, pp. 54-68
O'Connor, M.K., Kemp, B., Anstett, F., Christian, P., Ficaro, E.P., Frey, E., A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models (2002) J Nucl Cardiol, 9, pp. 361-376
Links, J.M., Becker, L.C., Rigo, P., Taillefer, R., Hanelin, L., Anstett, F., Combined corrections for attenuation, depth-dependent blur, and motion in cardiac SPECT: A multicenter trial (2000) J Nucl Cardiol, 7, pp. 414-425
Narayanan, M.V., King, M.A., Pretorius, P.H., Dahlberg, S.T., Spencer, F., Simon, E., Human-observer receiver-operating characteristic evaluation of attenuation, scatter, and resolution compensation strategies for 99mTc myocardial perfusion imaging (2003) J Nucl Med, 44, pp. 1725-1734
Wackers, F.J.T., Attenuation compensation of cardiac SPECT: A critical look at a confusing world (2002) J Nucl Cardiol, 9, pp. 438-440
Gallowitsch, H.J., Sykora, J., Mikosch, P., Kresnik, E., Unterweger, O., Molnar, M., Attenuation-corrected thallium-201 single-photon emission tomography using a gadolinium-153 moving line source: Clinical value and the impact of attenuation correction on the extent and severity of perfusion abnormal-ities (1998) Eur J Nucl Med, 25, pp. 220-228
Cerqueira, M.D., Weissman, N.J., Dilsizian, V., Jacobs, A.K., Kaul, S., Laskey, W.K., Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association (2002) Circulation, 105, pp. 539-542
Shehata, A.R., Ahlberg, A.W., White, M.P., Russell, A., Fleming, I.A., Levine, M.G., Dipyridamole-dobutamine stress with Tc-99m sestamibi tomographic myocardial perfusion imaging (1998) Am J Cardiol, 82, pp. 520-523
Van Train, K.F., Alreeda, J., Garcia, E.V., Cooke, C.D., Maddahi, J., Kiat, H., Quantitative same-day rest-stress technetium-99m-sestamibi SPECT: Definition and validation of stress normal limits and criteria for abnormality (1993) J Nucl Med, 34, pp. 1494-1502
Berman, D.S., Kang, X., Van Train, K.F., Lewin, H.C., Cohen, I., Areeda, J., Comparative prognostic value of automatic quantitative analysis versus semiquantitative visual analysis of exercise myocardial perfusion single-photon emission computed tomography (1998) J Am Coll Cardiol, 32, pp. 1987-1995
McClellan, J.R., Travin, M.I., Herman, S.D., Baron, J.I., Golub, R.J., Gallagher, J.J., Prognostic importance of scintigraphic left ventricular cavity dilation during intravenous dipyridamole technetium-99m sestamibi myocardial tomographic imaging in predicting coronary events (1997) Am J Cardiol, 79, pp. 600-605
Ioannidis, J.P., Trikalinos, T.A., Danias, P.G., Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: A meta-analysis (2002) J Am Coll Cardiol, 39, pp. 2059-2068
Bavelaar-Croon, C.D., Kayser, H.W., Van Der Wall, E.E., De Roos, A., Dibbets-Schneider, P., Pauwels, E.K., Left ventricular function: Correlation of quantitative gated SPECT and MR imaging over a wide range of values (2000) Radiology, 217, pp. 572-575
Cerqueira, M.D., The user friendly nuclear cardiology report: What needs to be considered and what needs to be included (1996) J Nucl Cardiol, 3, pp. 350-356
Wackers, F.J.T., Intersocietal Commission for the Accreditation of Nuclear Medicine Laboratories (ICANL) position statement on standardization and optimization of nuclear cardiology reports (2000) J Nucl Cardiol, 7, pp. 397-400
Pennell, D.J., Prvulovich, E., Image interpretation (1995) Nuclear Cardiology, pp. 56-79. , Ell PJ, editor. London: British Nuclear Medicine Society
Knuuti, M.J., Nuutila, P., Ruotsalainen, U., Saraste, M., Harkonen, R., Ahonen, A., Euglycemic hyperinsulinemic clamp and oral glucose load in stimulating myocardial glucose utilization during positron emission tomography (1992) J Nucl Med, 33, pp. 1255-1262
Berry, J.J., Baker, J.A., Pieper, K.S., Hanson, M.W., Hoffman, J.M., Coleman, R.E., The effect of metabolic milieu on cardiac PET imaging using fluorine-18-deoxyglucose and nitrogen-13-ammonia in normal volunteers (1991) J Nucl Med, 32, pp. 1518-1525
Knuuti, M.J., Yki-Jarvinen, H., Voipio-Pulkki, L.M., Maki, M., Ruotsalainen, U., Harkonen, R., Enhancement of myocardial [fluorine-18]fluorodeoxyglucose uptake by a nicotinic acid derivative (1994) J Nucl Med, 35, pp. 989-998
Schinkel, A.F., Bax, J.J., Valkema, R., Elhendy, A., Van Domburg, R.T., Vourvouri, E.C., Effect of diabetes mellitus on myocardial 18F-FDG SPECT using acipimox for the assessment of myocardial viability (2003) J Nucl Med, 44, pp. 877-883
McCord, M.E., Bacharach, S.L., Bonow, R.O., Dilsizian, V., Cuocolo, A., Freedman, N., Misalignment between PET transmission and emission scans: Its effect on myocardial imaging (1992) J Nucl Med, 33, pp. 1209-1214
Bergmann, S.R., Herrero, P., Markham, J., Weinheimer, C.J., Walsh, M.N., Non-invasive quantitation of myocardial blood flow in human subjects with oxygen-15 labelled water and positron emission tomography (1989) J Am Coll Cardiol, 14, pp. 639-652
Uren, N.G., Melin, J.A., De-Bruyne, B., Wijns, W., Baudhuin, T., Camici, P.G., Relation between myocardial blood flow and the severity of coronary-artery stenosis (1994) N Engl J Med, 330, pp. 1782-1788
Gropler, R.J., Lee, K.J., Moerlein, S.M., Siegel, B.A., Geltman, E.M., Regional variation in myocardial accumulation of 18F- fluorodeoxyglucose in fasted normal subjects (1990) J Am Coll Cardiol, 15, pp. 81A
Di Carli, M.F., Asgarzadie, F., Schelbert, H.R., Brunken, R.C., Laks, H., Phelps, M.E., Quantitative relation between myocardial viability and improvement in heart failure symptoms after revascularization in patients with ischemic cardiomyopathy (1995) Circulation, 92, pp. 3436-3444
Bax, J.J., Poldermans, D., Elhendy, A., Cornel, J.H., Boersma, E., Rambaldi, R., Improvement of left ventricular ejection fraction, heart failure symptoms and prognosis after revascularization in patients with chronic coronary artery disease and viable myocardium detected by dobutamine stress echocardiography (1999) J Am Coll Cardiol, 34, pp. 163-169
Gambhir, S.S., Schwaiger, M., Huang, S.C., Krivokapich, J., Schelbert, H.R., Nienaber, C.A., Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose (1989) J Nucl Med, 30, pp. 359-366
Blanksma, P.K., Willemsen, A.T., Meeder, J.G., De Jong, R.M., Anthonio, R.L., Pruim, J., Quantitative myocardial mapping of perfusion and metabolism using parametric polar map displays in cardiac PET (1995) J Nucl Med, 36, pp. 153-158